● Model: BM200-DI/I
● Input Signal: DC0~20mA / 4~20mA
● Output Signal: DC0~20mA / 4~20mA
● Channel Type: 1 in 1 out, 1 in 2 out, 2 in 2 out
● Power Supply: DC20~35V
● 35mm Din Rail Installation


① It can directly isolate the loop signal in the dangerous area from the signal in the safe area;
② It can allow the instrument to be grounded on site, especially there are many protective function circuits, and it allows live maintenance on site;
③ Compared with other devices, analog signal voltage isolator is still very good in signal processing.
| Type | BM200-DI/I-B11、BM200-DI/I-C12、BM200-DI/I-C22 |
| Channel type | 1 in 1 out, 1 in 2 out, 2 in 2 out |
| Input type | Current |
| Output signal | 0~20mA/4~20mA (Distribution voltage: 14.0V/20mA) |
| Output Signal | 0~20mA /4~20mA (safety side output); Load resistance: ≤550Ω |
| Transmission accuracy | 0.2% |
| Temperature drift | 50ppm |
| Response time | 5ms to reach 90% of final value |
| Supply voltage | 20~35V DC |
| Consumption | 24V power supply, 20mA output: ≤70mA (one in, one out)≤110mA (one in, two out)≤160mA (two in and two out) |
| Working temperature | -20℃~+60℃ |
| Storage temperature | -40℃~+80℃ |
| Relative humidity | ≤95%RH, no condensation, no corrosive gas place |
| Altitude | ≤2500m |
| Protection level | IP20 |
| Weight | About 110g (12.5mm shell)About 150g (22.5mm shell) |
| Installation | Din-rail mounted |
| Dielectric strength | Intrinsically safe end and non-intrinsically safe end ≥ 2500V AC; power supply and non-intrinsically safe end ≥ 500V AC |


BM200-DI/I-B11

BM200-DI/I-C12

BM200-DI/I-C22