BAK Series Split Core AC Current Transducer

Acrel BAK Series Split-core products utilize the principle of electromagnetic induction to perform real-time measurement of AC current in power grids. Using constant current and linear compensation technology, they isolate and convert the measured current into a standard DC signal output. Operating on a safe voltage of DC12V or 24V, they can be widely used in industrial automation fields.

  • Szybka i bezpieczna logistyka
  • Próbka dostępna

Technical Parameter

Accuracy Class Class 1
InputNominal ValueBAK20-ACurrent AC 0.5A, 50A, 200A, etc. AC0~(0.5~200A)
BAK50-AICurrent AC 60A, 300A, 600A, etc. AC0~(60~600A)
OverloadContinuous 1.2x, Instantaneous current 10x/5 seconds
Power Consumption≤1VA
Measurement Frequency45Hz~65Hz
OutputNominal ValueDC0/4~20mA,0~5/10V
Load Resistance≤500Ω when current output, ≥10KΩ when voltage output
CommunicationRS485 interface / Modbus-RTU protocol
Digital Output(DO)1 relay output, Normally Open (NO) contactsCapacity 2A/30VDC or 2A/250VAC
Indicators2 indicators: RUN (operational status), Alarm (DO status)
Response Time≤400ms
Power SupplyVoltageDC 12V or 24V
Power Consumption≤1W
Insulation Resistance>100MΩ
Dielectric Strength2.0kV/1min, 50Hz between Input/Output/Power Supply
Temperature Coefficient≤400ppm/℃ when -10℃~55℃
EnvironmentTemperatureOperating: -10℃~+55℃ Storage: -25℃~+70℃
Humidity≤93%RH, non-condensing, non-corrosive gas environment
Altitude≤2000m
WeightBAK20-AI approx. 242gBAK50-AI approx. 468g
MountingTS35 rail, or fixed to cabinet with screws

Type Selection

BAK - type selection_副本

Wiring

BAK - wiring - 1_副本
BAK - wiring - 2_副本

V+ —— Power Positive (Note: Do not reverse power positive and ground)

DO-、DO+ —— Digital Output (Switch) Interface

V- ——  Power Ground

A、B —— RS485 Interface

OUT- ——  Analog Output Negative

OUT+ ——  Analog Output Positive

Cable is through-hole (pass-through) input

Indicator Definitions:

RUN: Normal operation. When 485 communication is not connected, the RUN indicator shows green, blinking once per second. When the current sensor successfully connects to 485 communication, the RUN indicator blinks rapidly.

Alarm: After the alarm function is enabled, when the input current reaches 120% of the sensor's range, the Alarm indicator lights red steadily and the relay output closes. When the input current drops below 110% of the sensor's range, the Alarm indicator turns off. If the alarm function is not enabled, the Alarm indicator remains off and the relay does not close.

Notes:

(1) The device uses removable terminal blocks. It is recommended to use shielded wires with a cross-sectional area of 0.75mm² for the power, output, RS485 communication, and digital output interface sides.

(2) Please refer to the wiring diagram on the physical housing for specific wiring connections.

Dimension

BAK20-AI Dimension

BAK20-AI Dimension_副本

BAK50-AI Dimension

BAK50-AI Dimension_副本

Application

Cement Building Petrochemical Industry
Iron and Steel Metallurgy Rail Traffic