Programowalny jednofazowy miernik prądu AC AMC48-AI

Amperomierz prądu przemiennego serii AMC, wykorzystujący technologię próbkowania prądu przemiennego, może bezpośrednio mierzyć prąd sieci trójfazowej. Można go używać do lokalnego wyświetlania i podłączania przemysłowych urządzeń sterujących w celu utworzenia systemu kontroli pomiarów.

  • Szybka i bezpieczna logistyka
  • Próbka dostępna

AMC48-AI

    • Current  measurement
    • LED liquid crystal display
    • Single Phase Ammeter
    • Input: 1A or 5A

Parameters

Communication
RS485(Modbus-RTU)

Display
LCD display, set multiplying power

Rated U & I
AC current: AC1A, 5A

Accuracy
Active energy: Class 0.5

Installation
Panel mounted

Dimension(L*W*H)

Panel size (L×W): 48*48mm
Cutout(L×W): 45*45mm

Depth (H): 93mm

Consumption
Current: Power consumption< 0.5VA;
Auxiliary power supply: power consumption≤5VA

Auxiliary power supply
AC 220V



Technical Datasheet



Technical Parameter
Value






Input

Rated Value

Single phaseAC 100V,400V,660V(UL-L,Only 72/ 96)

AC current:AC1A,5A;

Overload

Voltage: 1.2 times rated value(continuous); 2 times rated value /1 second

Current:1.2 times rated value(continuous); 10 times rated value /1 second

Frequency

45Hz~65Hz

Power Consumption

Power consumption of each voltage,current input circuit is less than 0.5VA

AccuracyClass 0.5






Function

Display

LED or LCD

Communication

RS485,Modbus-RTU protocol;(1 start bit,8 data bit,1 stop bit,no parity)

Baud Rate 2400/4800/9600/19200 bps etc.

Alarm

1 channel passive relay,contact capacity 3A/30VDC,3A/250VAC, Used for high,low,unbalance alarm etc.

Analog

DC4~20mA,( load <500Ω)

(note:Shielded wire is specially selected for the above signal input and output)

Switching

Input:4 channel or 2 channel dry contact Input,built in power supply

Output:2 channel switching output,NO relay contact,capacity:3A/30VDC,3A/250VAC

Auxiliary Supply

AC/DC 85-265V

Power Consumption

<5VA

Insulation resistance

≥ 100MΩ

Power frequency withstand voltage

Between power supply set of terminals and signal input,output set of terminals 2kV/1min (RMS)

Between the shell and all set of terminals(except the set of terminals reference voltage less than 40V) AC 4kV



Environment

Temperature

Operation: -10℃~+55℃Storage: -25°C ~+70°C

Humidity

≤95%RH,no condensation,without corrosive gas

Altitude

≤ 2500m






Dimension

Wiring

Network

Installation

FAQ




Q: No display on power?


A: Check whether the supply voltage is within the operating voltage range.



Q: Incorrect reading of voltage,current,electricty,etc?


A: Checking that the voltage/current ratio setting are correct;

Checking whether the wiring mode setting is consistent with the actual situation;

Checking whether the voltage transformer and current transformer are in good condition.




Q: Abnormal communication?


A: Check whether the adress,baud rate,check bits in the communication;

Setting are consistent with the host computer;

Check whether the RS485 converter is normal;

Check the connection is corrent if the resistor above 120 ohm is connected in parallel at the communication end.



Package





MINIMUM PACKAGE







MINIMUM PAKAGE


Package dimensions(1 PC)

170*150*130mm

Pakage Weight(1 PC)

0.62Kg


WHOLE BOX PAKAGE


Package dimensions(16 PCS)

450*245*200mm

Pakage Weight(16 PCS)

3.66kG


PRODUCT HS CODE


9028301400

ATTENTION !

The above packing and weight data are only refer to model AMC48-AI.

For other models or optional functions, please contact the salesman for details, thank you for your cooperation!