EMS 3.0
EMS 2.0
Substation O&M System
2000MG Microgrid
2000ES Energy Storage
Renewable Energy Monitoring And Protection
PV O&M Cloud System
Power Monitoring System
Wireless Temperature Monitoring System
Energy Efficiency Management System
IOT EMS Solution
End-of-Line Energy Measurement Renovation
Data Center Energy Efficiency Management
Telecom Base Station Energy Management
Medical IT Isolated Power System
Smart Distribution Cabinet
Electrical Equipment O&M System
Nowadays, grid companies usually require photovoltaic grid-connected systems to be irreversible, that is, the electricity generated by photovoltaic grid-connected systems is consumed by local loads, and excess electricity is not allowed to supply to the grid. The system can regulate power generation in order to prevent the photovoltaic grid-connected system from generating reverse power.
Anti-reflux:
Functions
Measure power generation and the use of electricity,
Data refresh rate: 250ms,
Split-core CT, 300A current,
Communication: RS485 and grid-connected inverter or energy storage inverter
Application | Model | Certificate | Product |
Single-phase | AGF-AE-S | ANSI C12 | |
ACR10R-D10TE | CE | ||
Two-phase | AGF-AE-D | ANSI C12 UL 1741 | |
Three-phase | ACR10R-D10TE4 | CE |
DJSF1352-RN DC Energy Meter
Applicatio | Name | Functions |
DJSF1352/RN | Accuracy: 1, voltage output: ±12V Communication: infrared and RS485 communication, Modbus-RTU and 645 protocol DIN rail installation Support hall sensor or shunt input |
AGF Series Confluence Acquisition Device
Functions
Current specification: 20A, perforation connection
3 DI
Temperature measurement
Busbar voltage measurement: DC 1500V
LCD display
Name | Product |
Combiner box | |
PV Confluence Acquisition Device |
In recent years, in response to global warming and climate change caused by greenhouse gas emissions, major countries have focused on promoting electric vehicles to replace traditional fuel vehicles. And the construction of charging piles is very important in the promotion of new energy vehicles. Therefore, a large number of charging pile projects have emerged around the world.
Single-phase and three-phase AC, DC energy meters complies with the corresponding IEC standards and can be used in all kinds of AC and DC charging piles to realize charging energy measurement and can transmit electrical parameters in real-time through communication.
Item | Shape | Type | Function |
Single Phase AC Energy Meter | ADL10-E | Din rail mounted; single-phase 60A, 50/60Hz input; measurement of electrical parameters such as voltage, current, power, energy; RS485 communication (Modbus protocol). | |
ADL100-ET | Din rail mounted; single-phase 60A, 50/60Hz input; measurement of electrical parameters such as voltage, current, power, energy; RS485 communication (Modbus protocol). energy pulse output; optional multi tariff. | ||
ADL200 | Din rail mounted; single-phase 80A, 50/60Hz input; measurement of electrical parameters such as voltage, current, power, energy, etc.; RS485 communication (Modbus protocol); energy pulse output; optional multi tariff. | ||
Three Phase AC Energy Meter | ADL400 | Din rail mounted; three-phase 80A, 50/60Hz input; measurement of electrical parameters such as voltage, current, power, energy; RS485 communication (Modbus protocol); energy pulse output; optional multi tariff. | |
ADL3000-E | Din rail mounted; three-phase 80A, 50/60Hz input; measurement of electrical parameters such as voltage, current, power, energy; RS485 communication (Modbus protocol); energy pulse output; optional multi tariff. | ||
DC Energy Meter | PZ72(L)-DE | Panel mounted, measure DC voltage, current, power; measure DC energy; direct connect voltage 0-1000V; current measurement support 75mV output of shunt, support 0-5V, 0-20mA output of hall; RS485(Modbus protocol) | |
DJSF1352 | Wall mounted, measure DC voltage, current, power; measure DC energy; direct connect voltage 0-1000V; current measurement supports 75mV output of shunt, supports 0-5V, 0-20mA output of hall; RS485(Modbus protocol) | ||
DJSF1352-RN | Din-rail mounted, support optional two-channel DC voltage, current, power measurement; measure DC energy; direct connect voltage 0-1000V; current measurement support shunt 75mV output, support Hall sensor 0-5V, 0-20mA output; RS485 communication (Modbus protocol) | ||
Shunt | AFL-T | Common Specification: 300A/75mV | |
Hall Sensor | AHKC | Common Specification: 1000A/5V |