{"id":4682,"date":"2026-10-27T01:46:36","date_gmt":"2026-10-27T01:46:36","guid":{"rendered":"https:\/\/acrel.pl\/?post_type=product&#038;p=4682"},"modified":"2026-10-27T01:46:45","modified_gmt":"2026-10-27T01:46:45","slug":"ard2l-low-voltage-motor-protector","status":"publish","type":"product","link":"https:\/\/acrel.pl\/ru\/product\/ard2l-low-voltage-motor-protector\/","title":{"rendered":"ARD2(L) Low Voltage Motor Protector"},"content":{"rendered":"<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>General<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p>ARD2 smart motor protector can protect the motor during the running and provide the SOE fault event recorder. It is equipped with the RS485 remote communication interface and the DC4-20mA analog output, which is convenient to form a network system together with control machines like PLC and PC.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:image {\"id\":4687} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20210511030119_80054.png\" alt=\"\" class=\"wp-image-4687\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Function<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Model<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Type<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">ARD2<\/td><td class=\"has-text-align-center\" data-align=\"center\">LED<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">ARD2L<\/td><td class=\"has-text-align-center\" data-align=\"center\">LCD<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Additional features<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Code<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">RS485(Modbus-RTU)<\/td><td class=\"has-text-align-center\" data-align=\"center\">C<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Leakage protection<\/td><td class=\"has-text-align-center\" data-align=\"center\">L<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">4\uff5e20mA analog output<\/td><td class=\"has-text-align-center\" data-align=\"center\">M<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">2 switch input; 1 relay output (programmable 3)<\/td><td class=\"has-text-align-center\" data-align=\"center\">L<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">SOE record<\/td><td class=\"has-text-align-center\" data-align=\"center\">SR<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Alarm (programmable 2)<\/td><td class=\"has-text-align-center\" data-align=\"center\">J<\/td><\/tr><\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:paragraph -->\n<p>\u25cf Accuracy: Class 0.5<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf Frequency Range: 45-65Hz<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf Auxiliary power supply: AC85V~265V\/DC100V~350V<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf Pulse output: 1600-160000imp\/kWh<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf Power consumption\u226410VA<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf Installation: Panel mounted<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf Dimension(L*W*H): 96*78.5*48mm<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf Communication: RS485 (Modbus-RTU)<br><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Front Panel<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4691} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20210511084110_76846.png\" alt=\"\" class=\"wp-image-4691\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Installation&nbsp;Dimension<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4689} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20211112025058_99623.png\" alt=\"\" class=\"wp-image-4689\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Installation dimensions of protector(Unit: mm)<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4690} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20211112024954_56054.png\" alt=\"\" class=\"wp-image-4690\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Installation dimensions of transformer<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4692} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20211112024910_58993.png\" alt=\"\" class=\"wp-image-4692\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Description of LED display<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p>When install the meter, loosen the locking screw of the fixing bracket, remove the fixing bracket, insert the instrument into the mounting hole, install the fixing bracket and tighten the screw to make the instrument be firmly installed without loosening.Shape for clamp reed squeeze installation.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Typical Connection<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4688} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20211112024721_46434.png\" alt=\"\" class=\"wp-image-4688\"\/><\/figure>\n<!-- \/wp:image -->","protected":false},"excerpt":{"rendered":"\u25cf Suitable for motors with rated voltage of AC380V\/660V;\n\u25cf Optional leakage protection, RS485 communication, analog output, etc.\n\u25cf 2 channels DI passive dry node input, signal power supply with built-in DC24V power supply;\n\u25cf 4 channels DO output.\n\u25cf Communication: RS485 (Modbus-RTU)\n\u25cf Display: 4 digitals LED display\n\u25cf Rated U and I: AC380\/660V, rated current up to 800A","protected":false},"featured_media":4686,"template":"","productcat":[6,44],"class_list":["post-4682","product","type-product","status-publish","has-post-thumbnail","hentry","productcat-power-protection","productcat-motor-protection"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ARD2(L) Low Voltage Motor Protector - ACREL<\/title>\n<meta name=\"description\" content=\"ARD2 smart motor protector can protect the motor during the running and provide the SOE fault event recorder. It is equipped with the RS485 remote communication interface and the DC4-20mA analog output, which is convenient to form a network system together with control machines like PLC and PC.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/acrel.pl\/ru\/product\/medical-isolation-power-panels\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ARD2(L) Low Voltage Motor Protector - ACREL\" \/>\n<meta property=\"og:description\" content=\"ARD2 smart motor protector can protect the motor during the running and provide the SOE fault event recorder. It is equipped with the RS485 remote communication interface and the DC4-20mA analog output, which is convenient to form a network system together with control machines like PLC and PC.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/\" \/>\n<meta property=\"og:site_name\" content=\"ACREL\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-27T01:46:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/ARD2-4.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/\",\"url\":\"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/\",\"name\":\"ARD2(L) Low Voltage Motor Protector - ACREL\",\"isPartOf\":{\"@id\":\"https:\/\/acrel.pl\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/ARD2-4.jpg\",\"datePublished\":\"2026-10-27T01:46:36+00:00\",\"dateModified\":\"2026-10-27T01:46:45+00:00\",\"description\":\"ARD2 smart motor protector can protect the motor during the running and provide the SOE fault event recorder. It is equipped with the RS485 remote communication interface and the DC4-20mA analog output, which is convenient to form a network system together with control machines like PLC and PC.\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/#primaryimage\",\"url\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/ARD2-4.jpg\",\"contentUrl\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/ARD2-4.jpg\",\"width\":1000,\"height\":1000},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/acrel.pl\/#website\",\"url\":\"https:\/\/acrel.pl\/\",\"name\":\"ACREL\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/acrel.pl\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ARD2(L) Low Voltage Motor Protector - ACREL","description":"ARD2 smart motor protector can protect the motor during the running and provide the SOE fault event recorder. It is equipped with the RS485 remote communication interface and the DC4-20mA analog output, which is convenient to form a network system together with control machines like PLC and PC.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/acrel.pl\/ru\/product\/medical-isolation-power-panels\/","og_locale":"en_US","og_type":"article","og_title":"ARD2(L) Low Voltage Motor Protector - ACREL","og_description":"ARD2 smart motor protector can protect the motor during the running and provide the SOE fault event recorder. It is equipped with the RS485 remote communication interface and the DC4-20mA analog output, which is convenient to form a network system together with control machines like PLC and PC.","og_url":"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/","og_site_name":"ACREL","article_modified_time":"2026-10-27T01:46:45+00:00","og_image":[{"width":1000,"height":1000,"url":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/ARD2-4.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/","url":"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/","name":"ARD2(L) Low Voltage Motor Protector - ACREL","isPartOf":{"@id":"https:\/\/acrel.pl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/#primaryimage"},"image":{"@id":"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/#primaryimage"},"thumbnailUrl":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/ARD2-4.jpg","datePublished":"2026-10-27T01:46:36+00:00","dateModified":"2026-10-27T01:46:45+00:00","description":"ARD2 smart motor protector can protect the motor during the running and provide the SOE fault event recorder. It is equipped with the RS485 remote communication interface and the DC4-20mA analog output, which is convenient to form a network system together with control machines like PLC and PC.","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/#primaryimage","url":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/ARD2-4.jpg","contentUrl":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/ARD2-4.jpg","width":1000,"height":1000},{"@type":"WebSite","@id":"https:\/\/acrel.pl\/#website","url":"https:\/\/acrel.pl\/","name":"ACREL","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/acrel.pl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/product\/4682","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/media\/4686"}],"wp:attachment":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/media?parent=4682"}],"wp:term":[{"taxonomy":"productcat","embeddable":true,"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/productcat?post=4682"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}