{"id":4410,"date":"2026-10-16T07:00:48","date_gmt":"2026-10-16T07:00:48","guid":{"rendered":"https:\/\/acrel.pl\/?post_type=product&#038;p=4410"},"modified":"2026-10-16T07:00:59","modified_gmt":"2026-10-16T07:00:59","slug":"apview500-power-qualtiy-monitor-analyzer","status":"publish","type":"product","link":"https:\/\/acrel.pl\/ru\/product\/apview500-power-qualtiy-monitor-analyzer\/","title":{"rendered":"APView500 Power Qualtiy Monitor Analyzer"},"content":{"rendered":"<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>General<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p>Power quality monitor APView500 integrates a high-performance multi-core platform and an embedded operating system, and monitors power quality indexes stipulated in IEC61000-4-30 Testing and measurement techniques \u2013 Power quality measurement methods, and provides various functions such as harmonic analysis, waveform sampling, voltage dips\/swells\/interruptions monitoring, flicker monitoring , voltage unbalance monitoring, event recording and measurement control.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>It meets IEC 61000-4-30 Class A Edition 3.1 with respect to standardization of power quality index measurement methods, measurement accuracy of index parameters, clock synchronization, event alarms and others and satisfy the demands of power quality monitoring of power supply system up to 110kV.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>Therefore, it is widely applicable for power quality monitoring in chemical industry, steel industry, metallurgy industry, hospitals, data centers, transportation, construction industry and other industries.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Front Panel<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4417} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20250421084535_30220.png\" alt=\"\" class=\"wp-image-4417\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\">Technical Parameter<\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Rated Value<\/td><td class=\"has-text-align-center\" data-align=\"center\">AC voltage: AC\/DC220V, AC\/DC110V or DC48VAC current: AC1A, 5A;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Overload capacity<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.2In, continuous working20 times for 1 second<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">power supply<\/td><td class=\"has-text-align-center\" data-align=\"center\">Rated: AC\/DC220, AC\/DC110V or DC48VPermissible deviation: -20%-+20%Power consumption: \u226415W<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Power Consumption<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u22640.5VA (single phase)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Measuring rage<\/td><td class=\"has-text-align-center\" data-align=\"center\">0-1.2In<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Digital output<\/td><td class=\"has-text-align-center\" data-align=\"center\">Mechanical service life: \u226510000Output mode: Passive contactsSwitching capacity: \u22644000W or \u2264384VAOn-state current: \u226516A (AC250V\/DC24V) in the continuous mode;\u226530A for a short term (200ms)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">Accuracy<\/td><td class=\"has-text-align-center\" data-align=\"center\">Class 0.5<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">RMS Voltage: \u00b10.1%RMS Current: \u00b10.1%P, Q, S: \u00b10.2%Power factor: Class 0.5Voltage deviation: 0.1%Frequency deviation: \u00b10.001Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Communication<\/td><td class=\"has-text-align-center\" data-align=\"center\">RS485, Modbus-RTU protocol; Ethernet.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Three phase unbalance<\/td><td class=\"has-text-align-center\" data-align=\"center\">Voltage unbalance: \u00b10.15%Current unbalance: \u00b11%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Power frequency withstand voltage<\/td><td class=\"has-text-align-center\" data-align=\"center\">Between power supply set of terminals and signal input, output set of terminals 2kV\/1min (RMS)Between the shell and all set of terminals (except the set of terminals reference voltage less than 40V) AC 4kV<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\">Operation: -10\u2103\uff5e+55\u2103; Storage: -30\u2103-+80\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Humidity<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u226495%RH, no condensation, without corrosive gas<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Altitude<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u2264 2500m<\/td><\/tr><\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:image {\"id\":4415,\"sizeSlug\":\"full\",\"linkDestination\":\"none\"} -->\n<figure class=\"wp-block-image size-full\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/image-12.png\" alt=\"\" class=\"wp-image-4415\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:image {\"id\":4416,\"sizeSlug\":\"full\",\"linkDestination\":\"none\"} -->\n<figure class=\"wp-block-image size-full\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/image-13.png\" alt=\"\" class=\"wp-image-4416\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Dimension<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4418} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20250421084619_16394.png\" alt=\"\" class=\"wp-image-4418\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Installation<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4421} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20250421084643_84833.png\" alt=\"\" class=\"wp-image-4421\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Wiring<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4420} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20250421084721_65665.png\" alt=\"\" class=\"wp-image-4420\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Photo on Site<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4419} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20250421085342_50875.png\" alt=\"\" class=\"wp-image-4419\"\/><\/figure>\n<!-- \/wp:image -->","protected":false},"excerpt":{"rendered":"\u25cf 8 channels of AC voltage, 8 channels of AC current\n\u25cf 16 DO, 22 DI, Power supply: AC\/DC110V, 220V, DC48V\n\u25cf 2 RS485, support Modbus-RTU protocol\n\u25cf 4 Ethernet port, one is for device updates and others support Modbus-TCP\u3001IEC61850 MMS\u3001FTP protocol\n\u25cf 2nd-63rd Harmonic Monitor\n\u25cf Input Voltage: 3*57.7\/100V, 3*220\/380V, Input Current 1A\/5A","protected":false},"featured_media":4414,"template":"","productcat":[7,46],"class_list":["post-4410","product","type-product","status-publish","has-post-thumbnail","hentry","productcat-power-quality","productcat-power-quality-analyzer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>APView500 Power Qualtiy Monitor Analyzer - ACREL<\/title>\n<meta name=\"description\" content=\"Power quality monitor APView500 integrates a high-performance multi-core platform and an embedded operating system, and monitors power quality indexes stipulated in IEC61000-4-30 Testing and measurement techniques \u2013 Power quality measurement methods, and provides various functions such as harmonic analysis, waveform sampling, voltage dips\/swells\/interruptions monitoring, flicker monitoring , voltage unbalance monitoring, event recording and measurement control.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/acrel.pl\/ru\/pl\/product\/apview500-power-qualtiy-monitor-analyzer\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"APView500 Power Qualtiy Monitor Analyzer - ACREL\" \/>\n<meta property=\"og:description\" content=\"Power quality monitor APView500 integrates a high-performance multi-core platform and an embedded operating system, and monitors power quality indexes stipulated in IEC61000-4-30 Testing and measurement techniques \u2013 Power quality measurement methods, and provides various functions such as harmonic analysis, waveform sampling, voltage dips\/swells\/interruptions monitoring, flicker monitoring , voltage unbalance monitoring, event recording and measurement control.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/acrel.pl\/pl\/product\/apview500-power-qualtiy-monitor-analyzer\/\" \/>\n<meta property=\"og:site_name\" content=\"ACREL\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-16T07:00:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/APView500-Power-Quality-Monitor-5.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"1280\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/acrel.pl\/pl\/product\/apview500-power-qualtiy-monitor-analyzer\/\",\"url\":\"https:\/\/acrel.pl\/pl\/product\/apview500-power-qualtiy-monitor-analyzer\/\",\"name\":\"APView500 Power Qualtiy Monitor Analyzer - ACREL\",\"isPartOf\":{\"@id\":\"https:\/\/acrel.pl\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/acrel.pl\/pl\/product\/apview500-power-qualtiy-monitor-analyzer\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/acrel.pl\/pl\/product\/apview500-power-qualtiy-monitor-analyzer\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/APView500-Power-Quality-Monitor-5.png\",\"datePublished\":\"2026-10-16T07:00:48+00:00\",\"dateModified\":\"2026-10-16T07:00:59+00:00\",\"description\":\"Power quality monitor APView500 integrates a high-performance multi-core platform and an embedded operating system, and monitors power quality indexes stipulated in IEC61000-4-30 Testing and measurement techniques \u2013 Power quality measurement methods, and provides various functions such as harmonic analysis, waveform sampling, voltage dips\/swells\/interruptions monitoring, flicker monitoring , voltage unbalance monitoring, event recording and measurement control.\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/acrel.pl\/pl\/product\/apview500-power-qualtiy-monitor-analyzer\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/acrel.pl\/pl\/product\/apview500-power-qualtiy-monitor-analyzer\/#primaryimage\",\"url\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/APView500-Power-Quality-Monitor-5.png\",\"contentUrl\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/APView500-Power-Quality-Monitor-5.png\",\"width\":1280,\"height\":1280},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/acrel.pl\/#website\",\"url\":\"https:\/\/acrel.pl\/\",\"name\":\"ACREL\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/acrel.pl\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"APView500 Power Qualtiy Monitor Analyzer - ACREL","description":"Power quality monitor APView500 integrates a high-performance multi-core platform and an embedded operating system, and monitors power quality indexes stipulated in IEC61000-4-30 Testing and measurement techniques \u2013 Power quality measurement methods, and provides various functions such as harmonic analysis, waveform sampling, voltage dips\/swells\/interruptions monitoring, flicker monitoring , voltage unbalance monitoring, event recording and measurement control.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/acrel.pl\/ru\/pl\/product\/apview500-power-qualtiy-monitor-analyzer\/","og_locale":"en_US","og_type":"article","og_title":"APView500 Power Qualtiy Monitor Analyzer - ACREL","og_description":"Power quality monitor APView500 integrates a high-performance multi-core platform and an embedded operating system, and monitors power quality indexes stipulated in IEC61000-4-30 Testing and measurement techniques \u2013 Power quality measurement methods, and provides various functions such as harmonic analysis, waveform sampling, voltage dips\/swells\/interruptions monitoring, flicker monitoring , voltage unbalance monitoring, event recording and measurement control.","og_url":"https:\/\/acrel.pl\/pl\/product\/apview500-power-qualtiy-monitor-analyzer\/","og_site_name":"ACREL","article_modified_time":"2026-10-16T07:00:59+00:00","og_image":[{"width":1280,"height":1280,"url":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/APView500-Power-Quality-Monitor-5.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/acrel.pl\/pl\/product\/apview500-power-qualtiy-monitor-analyzer\/","url":"https:\/\/acrel.pl\/pl\/product\/apview500-power-qualtiy-monitor-analyzer\/","name":"APView500 Power Qualtiy Monitor Analyzer - ACREL","isPartOf":{"@id":"https:\/\/acrel.pl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/acrel.pl\/pl\/product\/apview500-power-qualtiy-monitor-analyzer\/#primaryimage"},"image":{"@id":"https:\/\/acrel.pl\/pl\/product\/apview500-power-qualtiy-monitor-analyzer\/#primaryimage"},"thumbnailUrl":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/APView500-Power-Quality-Monitor-5.png","datePublished":"2026-10-16T07:00:48+00:00","dateModified":"2026-10-16T07:00:59+00:00","description":"Power quality monitor APView500 integrates a high-performance multi-core platform and an embedded operating system, and monitors power quality indexes stipulated in IEC61000-4-30 Testing and measurement techniques \u2013 Power quality measurement methods, and provides various functions such as harmonic analysis, waveform sampling, voltage dips\/swells\/interruptions monitoring, flicker monitoring , voltage unbalance monitoring, event recording and measurement control.","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/acrel.pl\/pl\/product\/apview500-power-qualtiy-monitor-analyzer\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/acrel.pl\/pl\/product\/apview500-power-qualtiy-monitor-analyzer\/#primaryimage","url":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/APView500-Power-Quality-Monitor-5.png","contentUrl":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/APView500-Power-Quality-Monitor-5.png","width":1280,"height":1280},{"@type":"WebSite","@id":"https:\/\/acrel.pl\/#website","url":"https:\/\/acrel.pl\/","name":"ACREL","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/acrel.pl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/product\/4410","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/media\/4414"}],"wp:attachment":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/media?parent=4410"}],"wp:term":[{"taxonomy":"productcat","embeddable":true,"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/productcat?post=4410"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}