{"id":4120,"date":"2026-10-14T03:21:39","date_gmt":"2026-10-14T03:21:39","guid":{"rendered":"https:\/\/acrel.pl\/?post_type=product&#038;p=4120"},"modified":"2026-10-23T07:30:00","modified_gmt":"2026-10-23T07:30:00","slug":"am3se-protection-relay","status":"publish","type":"product","link":"https:\/\/acrel.pl\/ru\/product\/am3se-protection-relay\/","title":{"rendered":"AM3SE Protection Relay"},"content":{"rendered":"<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>General<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p>AM series microcomputer protection measurement and control device set protection, measurement, control in one, suitable for 35kV and below the voltage level of the user terminal substation (station), can achieve the protection and measurement and control of the user substation. Application fields cover power, water conservancy, transportation, petroleum, chemical, coal, metallurgy and other industries.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Front Panel<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4124} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20230518054652_42689.png\" alt=\"\" class=\"wp-image-4124\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\">Technical Parameter<\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"3\">Power supply<\/td><td class=\"has-text-align-center\" data-align=\"center\">Rated input<\/td><td class=\"has-text-align-center\" data-align=\"center\">AC\/DC220V, or AC\/DC110V, or DC48V, or DC24V<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Range<\/td><td class=\"has-text-align-center\" data-align=\"center\">Rared Voltage \u00d7 (1\u00b120%)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Consumption<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u226410W (DC)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"4\">Rated Voltage<\/td><td class=\"has-text-align-center\" data-align=\"center\">Rated input<\/td><td class=\"has-text-align-center\" data-align=\"center\">AC 100V\/100\/V<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Range<\/td><td class=\"has-text-align-center\" data-align=\"center\">1\uff5e120V<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Accuracy<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00b10.5%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Consumption<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u22640.5VA (single phase)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"4\">Rated Current<\/td><td class=\"has-text-align-center\" data-align=\"center\">Rated input<\/td><td class=\"has-text-align-center\" data-align=\"center\">AC 5A \/1A<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Range<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.04In\uff5e15In<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Accuracy<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00b10.5%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Consumption<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u22640.5VA (single phase)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"3\">Frequence<\/td><td class=\"has-text-align-center\" data-align=\"center\">Rated frequency<\/td><td class=\"has-text-align-center\" data-align=\"center\">50Hz or 60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Range<\/td><td class=\"has-text-align-center\" data-align=\"center\">45\uff5e55Hz or 60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Accuracy<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00b10.1Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"3\">DI<\/td><td class=\"has-text-align-center\" data-align=\"center\">Rated Voltage<\/td><td class=\"has-text-align-center\" data-align=\"center\">AC\/DC220V, or AC\/DC110V, or DC48V, or DC24V<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Range<\/td><td class=\"has-text-align-center\" data-align=\"center\">Rared Voltage \u00d7 (1\u00b120%)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Cconsumption<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u22641W (DC220V) (single channel)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"4\">DO<\/td><td class=\"has-text-align-center\" data-align=\"center\">Mechanical life<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u226510000<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Switching capacity<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u22651000W, L\/R = 40ms<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">On current<\/td><td class=\"has-text-align-center\" data-align=\"center\">continuous \u22655A, short time (200ms) \u226530A<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Interrupting capacity<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u226530W, L\/R = 40ms<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"3\">Environment<\/td><td class=\"has-text-align-center\" data-align=\"center\">Temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\">-10\u2103\uff5e\uff0b55\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Humidity<\/td><td class=\"has-text-align-center\" data-align=\"center\">5\uff05\uff5e95\uff05 (No condensation and freeze inside)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Altitude<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u22644000m<\/td><\/tr><\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Wiring<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4126} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20230518060247_51593.png\" alt=\"\" class=\"wp-image-4126\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:paragraph -->\n<p><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>LCD Display<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4128} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20230518054725_18773.png\" alt=\"\" class=\"wp-image-4128\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:image {\"id\":4125} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20230518054818_20236.png\" alt=\"\" class=\"wp-image-4125\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:image {\"id\":4127} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20230518054840_59738.png\" alt=\"\" class=\"wp-image-4127\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Installation Dimension<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4129} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20230518054914_19442.png\" alt=\"\" class=\"wp-image-4129\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Typical Connection<\/strong><strong><\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:heading {\"level\":4} -->\n<h4 class=\"wp-block-heading\"><img src=\"http:\/\/resourcewebsite.singoo.cc\/attached\/20211119024249_79030.jpg\" width=\"1100\" height=\"632\" alt=\"\"><\/h4>\n<!-- \/wp:heading -->","protected":false},"excerpt":{"rendered":"\u25cf A complete set of protection, related to the application\n\u25cf 3 current input, 3 voltage input, 11DI, 5DO\n\u25cf Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V, DC48V, DC24V\n\u25cf 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU\n\u25cf 1 GPS for GPS timing\n\u25cf More than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records\n\u25cf Powerful graphic programmable Logic","protected":false},"featured_media":4121,"template":"","productcat":[6,43],"class_list":["post-4120","product","type-product","status-publish","has-post-thumbnail","hentry","productcat-power-protection","productcat-protection-relay"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>AM3SE Protection Relay - ACREL<\/title>\n<meta name=\"description\" content=\"AM series microcomputer protection measurement and control device set protection, measurement, control in one, suitable for 35kV and below the voltage level of the user terminal substation (station), can achieve the protection and measurement and control of the user substation. Application fields cover power, water conservancy, transportation, petroleum, chemical, coal, metallurgy and other industries.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/acrel.pl\/ru\/product\/am3se-protection-relay\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"AM3SE Protection Relay - ACREL\" \/>\n<meta property=\"og:description\" content=\"AM series microcomputer protection measurement and control device set protection, measurement, control in one, suitable for 35kV and below the voltage level of the user terminal substation (station), can achieve the protection and measurement and control of the user substation. Application fields cover power, water conservancy, transportation, petroleum, chemical, coal, metallurgy and other industries.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/acrel.pl\/product\/am3se-protection-relay\/\" \/>\n<meta property=\"og:site_name\" content=\"ACREL\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-23T07:30:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/1-9.png\" \/>\n\t<meta property=\"og:image:width\" content=\"554\" \/>\n\t<meta property=\"og:image:height\" content=\"509\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/acrel.pl\/product\/am3se-protection-relay\/\",\"url\":\"https:\/\/acrel.pl\/product\/am3se-protection-relay\/\",\"name\":\"AM3SE Protection Relay - ACREL\",\"isPartOf\":{\"@id\":\"https:\/\/acrel.pl\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/acrel.pl\/product\/am3se-protection-relay\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/acrel.pl\/product\/am3se-protection-relay\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/1-9.png\",\"datePublished\":\"2026-10-14T03:21:39+00:00\",\"dateModified\":\"2026-10-23T07:30:00+00:00\",\"description\":\"AM series microcomputer protection measurement and control device set protection, measurement, control in one, suitable for 35kV and below the voltage level of the user terminal substation (station), can achieve the protection and measurement and control of the user substation. Application fields cover power, water conservancy, transportation, petroleum, chemical, coal, metallurgy and other industries.\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/acrel.pl\/product\/am3se-protection-relay\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/acrel.pl\/product\/am3se-protection-relay\/#primaryimage\",\"url\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/1-9.png\",\"contentUrl\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/1-9.png\",\"width\":554,\"height\":509},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/acrel.pl\/#website\",\"url\":\"https:\/\/acrel.pl\/\",\"name\":\"ACREL\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/acrel.pl\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"AM3SE Protection Relay - ACREL","description":"AM series microcomputer protection measurement and control device set protection, measurement, control in one, suitable for 35kV and below the voltage level of the user terminal substation (station), can achieve the protection and measurement and control of the user substation. Application fields cover power, water conservancy, transportation, petroleum, chemical, coal, metallurgy and other industries.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/acrel.pl\/ru\/product\/am3se-protection-relay\/","og_locale":"en_US","og_type":"article","og_title":"AM3SE Protection Relay - ACREL","og_description":"AM series microcomputer protection measurement and control device set protection, measurement, control in one, suitable for 35kV and below the voltage level of the user terminal substation (station), can achieve the protection and measurement and control of the user substation. Application fields cover power, water conservancy, transportation, petroleum, chemical, coal, metallurgy and other industries.","og_url":"https:\/\/acrel.pl\/product\/am3se-protection-relay\/","og_site_name":"ACREL","article_modified_time":"2026-10-23T07:30:00+00:00","og_image":[{"width":554,"height":509,"url":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/1-9.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/acrel.pl\/product\/am3se-protection-relay\/","url":"https:\/\/acrel.pl\/product\/am3se-protection-relay\/","name":"AM3SE Protection Relay - ACREL","isPartOf":{"@id":"https:\/\/acrel.pl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/acrel.pl\/product\/am3se-protection-relay\/#primaryimage"},"image":{"@id":"https:\/\/acrel.pl\/product\/am3se-protection-relay\/#primaryimage"},"thumbnailUrl":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/1-9.png","datePublished":"2026-10-14T03:21:39+00:00","dateModified":"2026-10-23T07:30:00+00:00","description":"AM series microcomputer protection measurement and control device set protection, measurement, control in one, suitable for 35kV and below the voltage level of the user terminal substation (station), can achieve the protection and measurement and control of the user substation. Application fields cover power, water conservancy, transportation, petroleum, chemical, coal, metallurgy and other industries.","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/acrel.pl\/product\/am3se-protection-relay\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/acrel.pl\/product\/am3se-protection-relay\/#primaryimage","url":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/1-9.png","contentUrl":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/1-9.png","width":554,"height":509},{"@type":"WebSite","@id":"https:\/\/acrel.pl\/#website","url":"https:\/\/acrel.pl\/","name":"ACREL","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/acrel.pl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/product\/4120","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/media\/4121"}],"wp:attachment":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/media?parent=4120"}],"wp:term":[{"taxonomy":"productcat","embeddable":true,"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/productcat?post=4120"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}