{"id":3987,"date":"2026-10-12T06:33:36","date_gmt":"2026-10-12T06:33:36","guid":{"rendered":"https:\/\/acrel.pl\/?post_type=product&#038;p=3987"},"modified":"2026-10-12T08:21:07","modified_gmt":"2026-10-12T08:21:07","slug":"abat100-lead-acid-battery-monitoring-device","status":"publish","type":"product","link":"https:\/\/acrel.pl\/ru\/product\/abat100-lead-acid-battery-monitoring-device\/","title":{"rendered":"ABAT100 Lead Acid Battery Monitoring Device"},"content":{"rendered":"<!-- wp:heading -->\n<h2 class=\"wp-block-heading\">Features<\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p>\u25cf Monitoring Capability:&nbsp;One S-module monitors one battery<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf&nbsp;Monitoring Scope:&nbsp;2V, 6V, 12V battery with capacity less than 3000AH<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf&nbsp;Single internal resistance:&nbsp;50\uff5e65535u\u03a9<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf&nbsp;Negative temperature:&nbsp;-5\u2103\uff5e+105\u2103<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf&nbsp;Communication Interface:&nbsp;UART port, support MODBUS protocol<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf&nbsp;Insulation withstand voltage: 2000VAC<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf Battery Type:&nbsp;Lead acid battery<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Model<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Function Description<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">ABAT100-HS<\/td><td class=\"has-text-align-center\" data-align=\"center\">DC24V input, one to manage a group of batteries, up to 120 batteries in a group.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">ABAT100-S-02<\/td><td class=\"has-text-align-center\" data-align=\"center\">Monitor one 2V battery, monitor battery voltage, internal resistance and negative terminal temperature.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">ABAT100-S-06<\/td><td class=\"has-text-align-center\" data-align=\"center\">Monitor one 6V battery, monitor battery voltage, internal resistance and negative terminal temperature.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">ABAT100-S-12<\/td><td class=\"has-text-align-center\" data-align=\"center\">Monitor one 12V battery, monitoring battery voltage, internal resistance and negative terminal temperature.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">ABAT100-C<\/td><td class=\"has-text-align-center\" data-align=\"center\">Monitor one charge\/discharge current with an ambient temperature with a maximum current range of 1000A.<\/td><\/tr><\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:paragraph -->\n<p><strong>ABAT100-HS Collector Module Technical Parameters<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Function<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Description<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Display<\/td><td class=\"has-text-align-center\" data-align=\"center\">Real-time data display, graphs, histogram display<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Historical Data<\/td><td class=\"has-text-align-center\" data-align=\"center\">Query and export of equipment operation history, charging and&nbsp;discharging records and monitoring events<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Parameter Configuration<\/td><td class=\"has-text-align-center\" data-align=\"center\">Provide basic information management functions<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Communication protocol<\/td><td class=\"has-text-align-center\" data-align=\"center\">MODBUS-RTU<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Alarm mode<\/td><td class=\"has-text-align-center\" data-align=\"center\">Local audible and visual alarm, indicator alarm, SMS alarm, etc.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Capacity estimation<\/td><td class=\"has-text-align-center\" data-align=\"center\">Group batteries SOC, SOH estimation; single battery SOC, SOH&nbsp;estimation<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Regular inspection<\/td><td class=\"has-text-align-center\" data-align=\"center\">Intelligent judgment of the current state and automatic issuance of test&nbsp;commands<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Indicator light<\/td><td class=\"has-text-align-center\" data-align=\"center\">Red and green LED lights, green light as the power light, red light as the&nbsp;indicator light<\/td><\/tr><\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Technical parameters<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Description<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Working Environment<\/td><td class=\"has-text-align-center\" data-align=\"center\">Operating temperature: -10\u2103\uff5e50\u2103Relative humidity: 5%~95%Atmospheric pressure intensity: 80~110kPa<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Management Capability<\/td><td class=\"has-text-align-center\" data-align=\"center\">One collector can monitor a maximum of total 120 batteries<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Alarm Type<\/td><td class=\"has-text-align-center\" data-align=\"center\">Group&nbsp;voltage&nbsp;overcharge\/discharge,&nbsp;single&nbsp;voltage&nbsp;overcharge\/discharge, current overcharge\/discharge, high internal&nbsp;resistance of single unit, abnormal communication, etc.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Power Supply<\/td><td class=\"has-text-align-center\" data-align=\"center\">DC24V<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Protection<\/td><td class=\"has-text-align-center\" data-align=\"center\">With overvoltage and short circuit protection<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Communication&nbsp;Interface<\/td><td class=\"has-text-align-center\" data-align=\"center\">With RS485 communication port, support MODBUS\/RTU<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Insulation withstand&nbsp;voltage<\/td><td class=\"has-text-align-center\" data-align=\"center\">2000VAC<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Installation method<\/td><td class=\"has-text-align-center\" data-align=\"center\">Tie-down mounting or adhesive mounting<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Weight<\/td><td class=\"has-text-align-center\" data-align=\"center\">90g<\/td><\/tr><\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:paragraph -->\n<p><strong>ABAT100-S Single Battery Monitoring Module<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Function<\/td><td class=\"has-text-align-center\" data-align=\"center\">Description<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Online monitoring<\/td><td class=\"has-text-align-center\" data-align=\"center\">Online monitoring 24 hours a day, one battery per module, monitoring voltage,&nbsp;internal resistance and negative terminal temperature<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">High accuracy measurement<\/td><td class=\"has-text-align-center\" data-align=\"center\">Internal resistance measurement error as low as 1%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Battery internal resistance test<\/td><td class=\"has-text-align-center\" data-align=\"center\">Automatic periodic measurement of the internal resistance of each battery&nbsp;controlled by&nbsp;the&nbsp;collector<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Low power design<\/td><td class=\"has-text-align-center\" data-align=\"center\">Manual entry into low power mode, S-module draws current from the battery&nbsp;down to 0.5mA<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Anti-jamming design<\/td><td class=\"has-text-align-center\" data-align=\"center\">High anti-interference design, can block the ripple interference of high power high&nbsp;frequency UPS<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Communication protocol<\/td><td class=\"has-text-align-center\" data-align=\"center\">MODBUS-RTU protocol<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Installation method<\/td><td class=\"has-text-align-center\" data-align=\"center\">Tie-down mounting or adhesive mounting<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Indicator light<\/td><td class=\"has-text-align-center\" data-align=\"center\">Red and green LED lights, green light as the power light, red light as the indicator&nbsp;light<\/td><\/tr><\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Technical parameters<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Description<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Working&nbsp;Environment<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Operating temperature: -10\u2103\uff5e50\u2103Relative humidity: 5%~95%Atmospheric pressure intensity: 80~110kPa<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Monitoring&nbsp;Capability<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">One S-module monitors one battery<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Monitoring Scope<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">2V, 6V, 12V battery with capacity less than 3000AH<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"4\">Measurement range&nbsp;and accuracy<\/td><td class=\"has-text-align-center\" data-align=\"center\">Measurement content<\/td><td class=\"has-text-align-center\" data-align=\"center\">Scope<\/td><td class=\"has-text-align-center\" data-align=\"center\">Accuracy<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Single Voltage<\/td><td class=\"has-text-align-center\" data-align=\"center\">2V, 6V, 12V<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00b10.1%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Single internal resistance<\/td><td class=\"has-text-align-center\" data-align=\"center\">50\uff5e65535u\u03a9<\/td><td class=\"has-text-align-center\" data-align=\"center\">(Resolution) 1u\u03a9<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Negative temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\">-5\u2103\uff5e+105\u2103<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00b11\u00b0C<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Power requirements<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Directly from the monitored battery, 2V module normal operation of the&nbsp;absorption current of 10mA, the&nbsp;maximum is not more&nbsp;than&nbsp;13mA, 6V, 12V module normal operation of the absorption current&nbsp;of 5mA, the maximum is not more than 7mA, different modules absorption current&nbsp;consistency is very high<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Protection<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Measuring circuit and power circuit with two levels of protection, with&nbsp;reverse connection protection and opto-isolation<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Communication&nbsp;Interface<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">UART port, support MODBUS protocol<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Insulation withstand&nbsp;voltage<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">2000VAC<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Weight<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">90g<\/td><\/tr><\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:paragraph -->\n<p><strong>ABAT100-C Module<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Function<\/td><td>Description<\/td><\/tr><tr><td>High stability<\/td><td>Reliable and stable long-term operation<\/td><\/tr><tr><td>Anti-jamming&nbsp;design<\/td><td>High anti-interference design, can block the ripple interference of high power&nbsp;high frequency UPS<\/td><\/tr><tr><td>Communication&nbsp;protocol<\/td><td>MODBUS-RTU Protocol<\/td><\/tr><tr><td>Installation&nbsp;method<\/td><td>Tie-down mounting or adhesive mounting<\/td><\/tr><tr><td>Indicator light<\/td><td>Red and green LED lights, green light as the power light, red light as the&nbsp;indicator light<\/td><\/tr><\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Technical parameters<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Description<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Working&nbsp;Environment<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Operating temperature: -10\u2103\uff5e50\u2103Relative humidity: 5%~95%Atmospheric pressure intensity: 80~110kPa<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Monitoring&nbsp;Capability<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">One C-module monitors the charge and discharge current of a group of&nbsp;batteries against the ambient temperature<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Monitoring Scope<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">2V, 6V, 12V battery pack<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"3\">Measurement range&nbsp;and accuracy<\/td><td class=\"has-text-align-center\" data-align=\"center\">Measurement content<\/td><td class=\"has-text-align-center\" data-align=\"center\">Scope<\/td><td class=\"has-text-align-center\" data-align=\"center\">Accuracy<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Charging and&nbsp;discharging current<\/td><td class=\"has-text-align-center\" data-align=\"center\">0~1000A<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00b11%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Ambient temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\">-5\u2103\uff5e+105\u2103<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00b11\u00b0C<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Power requirements<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">DC24V, 1W<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Protection<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Measurement circuit and power circuit with two levels of protection<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Communication&nbsp;Interface<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">UART port, support MODBUS protocol<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Insulation withstand&nbsp;voltage<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">2000VAC<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Weight<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">90g<\/td><\/tr><\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Dimension<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":3998} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20240307113023_88477.png\" alt=\"\" class=\"wp-image-3998\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Typical Connection<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":3999} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20240307112009_73972.png\" alt=\"\" class=\"wp-image-3999\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:image {\"id\":4000,\"width\":\"1043px\",\"height\":\"auto\",\"aspectRatio\":\"1.2270588235294118\"} -->\n<figure class=\"wp-block-image is-resized\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20240307112045_82897.png\" alt=\"\" class=\"wp-image-4000\" style=\"aspect-ratio:1.2270588235294118;width:1043px;height:auto\" title=\"\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Photos on Site<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":3997,\"sizeSlug\":\"full\",\"linkDestination\":\"none\"} -->\n<figure class=\"wp-block-image size-full\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/\u73b0\u573a\u56fe\u72471-4.png\" alt=\"\" class=\"wp-image-3997\"\/><\/figure>\n<!-- \/wp:image -->","protected":false},"excerpt":{"rendered":"Acrel ABAT100 series battery online monitoring system can provide battery operation information such as voltage, internal resistance and internal temperature, including SOC and SOH, and can provide early warning and battery equalization for failed batteries to guarantee battery pack backup time and extend battery pack life. The system has monitoring functions, and is easy to install, maintain and access.","protected":false},"featured_media":3989,"template":"","productcat":[9,188],"class_list":["post-3987","product","type-product","status-publish","has-post-thumbnail","hentry","productcat-power-sensor","productcat-lead-acid-battery-monitoring"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ABAT100 Lead Acid Battery Monitoring Device - ACREL<\/title>\n<meta name=\"description\" content=\"The system mainly consists of ABAT100-S single battery monitoring module, ABAT100-C group battery monitoring module, ABAT100-HS collector module and touch screen, etc. The alarm and real-time data can be queried and parameters can be set through the touch screen, and the monitoring platform can be selected to realize networked centralized management.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/acrel.pl\/ru\/pl\/product\/abat100-lead-acid-battery-monitoring-device\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ABAT100 Lead Acid Battery Monitoring Device - ACREL\" \/>\n<meta property=\"og:description\" content=\"The system mainly consists of ABAT100-S single battery monitoring module, ABAT100-C group battery monitoring module, ABAT100-HS collector module and touch screen, etc. The alarm and real-time data can be queried and parameters can be set through the touch screen, and the monitoring platform can be selected to realize networked centralized management.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/acrel.pl\/pl\/product\/abat100-lead-acid-battery-monitoring-device\/\" \/>\n<meta property=\"og:site_name\" content=\"ACREL\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-12T08:21:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/3.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1707\" \/>\n\t<meta property=\"og:image:height\" content=\"1707\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/acrel.pl\/pl\/product\/abat100-lead-acid-battery-monitoring-device\/\",\"url\":\"https:\/\/acrel.pl\/pl\/product\/abat100-lead-acid-battery-monitoring-device\/\",\"name\":\"ABAT100 Lead Acid Battery Monitoring Device - ACREL\",\"isPartOf\":{\"@id\":\"https:\/\/acrel.pl\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/acrel.pl\/pl\/product\/abat100-lead-acid-battery-monitoring-device\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/acrel.pl\/pl\/product\/abat100-lead-acid-battery-monitoring-device\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/3.jpg\",\"datePublished\":\"2026-10-12T06:33:36+00:00\",\"dateModified\":\"2026-10-12T08:21:07+00:00\",\"description\":\"The system mainly consists of ABAT100-S single battery monitoring module, ABAT100-C group battery monitoring module, ABAT100-HS collector module and touch screen, etc. The alarm and real-time data can be queried and parameters can be set through the touch screen, and the monitoring platform can be selected to realize networked centralized management.\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/acrel.pl\/pl\/product\/abat100-lead-acid-battery-monitoring-device\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/acrel.pl\/pl\/product\/abat100-lead-acid-battery-monitoring-device\/#primaryimage\",\"url\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/3.jpg\",\"contentUrl\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/3.jpg\",\"width\":1707,\"height\":1707},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/acrel.pl\/#website\",\"url\":\"https:\/\/acrel.pl\/\",\"name\":\"ACREL\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/acrel.pl\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ABAT100 Lead Acid Battery Monitoring Device - ACREL","description":"The system mainly consists of ABAT100-S single battery monitoring module, ABAT100-C group battery monitoring module, ABAT100-HS collector module and touch screen, etc. The alarm and real-time data can be queried and parameters can be set through the touch screen, and the monitoring platform can be selected to realize networked centralized management.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/acrel.pl\/ru\/pl\/product\/abat100-lead-acid-battery-monitoring-device\/","og_locale":"en_US","og_type":"article","og_title":"ABAT100 Lead Acid Battery Monitoring Device - ACREL","og_description":"The system mainly consists of ABAT100-S single battery monitoring module, ABAT100-C group battery monitoring module, ABAT100-HS collector module and touch screen, etc. The alarm and real-time data can be queried and parameters can be set through the touch screen, and the monitoring platform can be selected to realize networked centralized management.","og_url":"https:\/\/acrel.pl\/pl\/product\/abat100-lead-acid-battery-monitoring-device\/","og_site_name":"ACREL","article_modified_time":"2026-10-12T08:21:07+00:00","og_image":[{"width":1707,"height":1707,"url":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/3.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/acrel.pl\/pl\/product\/abat100-lead-acid-battery-monitoring-device\/","url":"https:\/\/acrel.pl\/pl\/product\/abat100-lead-acid-battery-monitoring-device\/","name":"ABAT100 Lead Acid Battery Monitoring Device - ACREL","isPartOf":{"@id":"https:\/\/acrel.pl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/acrel.pl\/pl\/product\/abat100-lead-acid-battery-monitoring-device\/#primaryimage"},"image":{"@id":"https:\/\/acrel.pl\/pl\/product\/abat100-lead-acid-battery-monitoring-device\/#primaryimage"},"thumbnailUrl":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/3.jpg","datePublished":"2026-10-12T06:33:36+00:00","dateModified":"2026-10-12T08:21:07+00:00","description":"The system mainly consists of ABAT100-S single battery monitoring module, ABAT100-C group battery monitoring module, ABAT100-HS collector module and touch screen, etc. The alarm and real-time data can be queried and parameters can be set through the touch screen, and the monitoring platform can be selected to realize networked centralized management.","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/acrel.pl\/pl\/product\/abat100-lead-acid-battery-monitoring-device\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/acrel.pl\/pl\/product\/abat100-lead-acid-battery-monitoring-device\/#primaryimage","url":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/3.jpg","contentUrl":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/3.jpg","width":1707,"height":1707},{"@type":"WebSite","@id":"https:\/\/acrel.pl\/#website","url":"https:\/\/acrel.pl\/","name":"ACREL","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/acrel.pl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/product\/3987","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/media\/3989"}],"wp:attachment":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/media?parent=3987"}],"wp:term":[{"taxonomy":"productcat","embeddable":true,"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/productcat?post=3987"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}