{"id":3643,"date":"2026-10-13T08:55:37","date_gmt":"2026-10-13T08:55:37","guid":{"rendered":"https:\/\/acrel.pl\/?post_type=product&#038;p=3643"},"modified":"2026-10-27T02:11:55","modified_gmt":"2026-10-27T02:11:55","slug":"acrel-alp220-ef-low-voltage-earth-fault-relay","status":"publish","type":"product","link":"https:\/\/acrel.pl\/ru\/product\/acrel-alp220-ef-low-voltage-earth-fault-relay\/","title":{"rendered":"Acrel\u00a0ALP220-EF Low-voltage Earth Fault Relay"},"content":{"rendered":"<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Front Panel<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/resourcewebsite.singoo.cc\/attached\/20260821082703_39122.png\" alt=\"\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Technical Parameters<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:table {\"align\":\"center\"} -->\n<figure class=\"wp-block-table aligncenter\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Technical parameter<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Qualification<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">Accessory power supply<\/td><td class=\"has-text-align-center\" data-align=\"center\">Voltage range<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">AC\/DC 85\uff5e265V<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Power dissipation<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"3\">Import<\/td><td class=\"has-text-align-center\" data-align=\"center\">Current specifications<\/td><td class=\"has-text-align-center\" data-align=\"center\">ABCN (4-channel): 1A\/5A<\/td><td class=\"has-text-align-center\" data-align=\"center\">10%Ie\uff5e1000%Ie \u00b12%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Residual currentspecification<\/td><td class=\"has-text-align-center\" data-align=\"center\">30mA-1000mA<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00b12%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Frequency<\/td><td class=\"has-text-align-center\" data-align=\"center\">45Hz-65Hz<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00b10.2Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">Output<\/td><td class=\"has-text-align-center\" data-align=\"center\">Output method<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Dual-channel single-pole double-throw switch<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Output capacity<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Resistive load; AC 250 V 5 A \/ DC 30 V 5 A<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"7\">Installation andUsage Environment<\/td><td class=\"has-text-align-center\" data-align=\"center\">Workplace Scenario<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">No direct exposure to rain or snow; no corrosive gases; no severe vibration<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Relative humidity<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">\u226495% RH, no condensation<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Working temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">-20\u2103~+70\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Storage temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">-40\u2103~+70\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Height<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">\u22642000m<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Way to install<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Embedded installation: 88\u00d788 (mm)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Levels of protection<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Panel: IP54; Terminals: IP20<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Security classification<\/td><td class=\"has-text-align-center\" data-align=\"center\">EMC<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Level III<\/td><\/tr><\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Functional Configuration<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Function<\/td><td class=\"has-text-align-center\" data-align=\"center\">Standard configuration<\/td><td class=\"has-text-align-center\" data-align=\"center\">Optional<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"3\">Measurement Function<\/td><td class=\"has-text-align-center\" data-align=\"center\">Three-phase alternating current<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Neutral conductor current<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Residual current<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"6\">Defencive function<\/td><td class=\"has-text-align-center\" data-align=\"center\">Inverse-time overcurrent protection<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Inverse Time Grounding<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Three-stage time-delayedovercurrent protection<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Three-stage time-delayedground fault protection<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Current imbalance<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Leakage current<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Communication Function<\/td><td class=\"has-text-align-center\" data-align=\"center\">Modbus-RTU<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Digital output function<\/td><td class=\"has-text-align-center\" data-align=\"center\">2 Single-pole double-throw switch<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">Record Function<\/td><td class=\"has-text-align-center\" data-align=\"center\">20 Single fault record<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">20 Event Record<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Display Function<\/td><td class=\"has-text-align-center\" data-align=\"center\">Liquid-crystal display<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">Setpoint Setting Function&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\">Operation Panel Modification<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Communication Amendment<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Dimension<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4054,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\n<figure class=\"wp-block-image size-large\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/08\/9e967299-330c-40fe-b404-abf9131f651b-1024x411.png\" alt=\"\" class=\"wp-image-4054\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Wiring<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"width\":\"600px\",\"height\":\"auto\",\"aspectRatio\":\"1.1152416356877324\"} -->\n<figure class=\"wp-block-image is-resized\"><img src=\"https:\/\/resourcewebsite.singoo.cc\/attached\/20260821082056_19180.png\" alt=\"\" style=\"aspect-ratio:1.1152416356877324;width:600px;height:auto\" title=\"\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Three-Phase Four-Wire Connection<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"width\":\"600px\",\"height\":\"auto\",\"aspectRatio\":\"1.1152416356877324\"} -->\n<figure class=\"wp-block-image is-resized\"><img src=\"https:\/\/resourcewebsite.singoo.cc\/attached\/20260821082148_10057.png\" alt=\"\" style=\"aspect-ratio:1.1152416356877324;width:600px;height:auto\" title=\"\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Application<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4055,\"sizeSlug\":\"full\",\"linkDestination\":\"none\"} -->\n<figure class=\"wp-block-image size-full\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/08\/45842c97-51ec-4e30-b3de-8de6ca24f56d.png\" alt=\"\" class=\"wp-image-4055\"\/><\/figure>\n<!-- \/wp:image -->","protected":false},"excerpt":{"rendered":"\u25cf Inverse-time Overcurrent & Earth-fault\n\u25cf Three-stage Definite-time Overcurrent & Earth-fault\n\u25cf Current Unbalance Protection\n\u25cf Residual Current Monitoring","protected":false},"featured_media":4693,"template":"","productcat":[6,44],"class_list":["post-3643","product","type-product","status-publish","has-post-thumbnail","hentry","productcat-power-protection","productcat-motor-protection"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Acrel\u00a0ALP220-EF Low-voltage Earth Fault Relay - ACREL<\/title>\n<meta name=\"description\" content=\"Acrel ALP220-EF Earth Fault Overcurrent Relay is designed for low-voltage applications (up to 380 V) where it is necessary to monitor the system&#039;s ground current and provide protection when the ground current exceeds the permissible limit. This relay features an LCD display, Modbus-RTU communication capability, system current measurement, three- phase current overcurrent protection, ground current overcurrent protection, residual current measurement, residual current overcurrent protection, fault logging, and event logging functions.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/acrel.pl\/ru\/product\/medical-isolation-power-panels\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Acrel\u00a0ALP220-EF Low-voltage Earth Fault Relay - ACREL\" \/>\n<meta property=\"og:description\" content=\"Acrel ALP220-EF Earth Fault Overcurrent Relay is designed for low-voltage applications (up to 380 V) where it is necessary to monitor the system&#039;s ground current and provide protection when the ground current exceeds the permissible limit. This relay features an LCD display, Modbus-RTU communication capability, system current measurement, three- phase current overcurrent protection, ground current overcurrent protection, residual current measurement, residual current overcurrent protection, fault logging, and event logging functions.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/\" \/>\n<meta property=\"og:site_name\" content=\"ACREL\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-27T02:11:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/1381afb4-7a36-4d7d-bb44-8ded3d5437e6.png\" \/>\n\t<meta property=\"og:image:width\" content=\"710\" \/>\n\t<meta property=\"og:image:height\" content=\"634\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/\",\"url\":\"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/\",\"name\":\"Acrel\u00a0ALP220-EF Low-voltage Earth Fault Relay - ACREL\",\"isPartOf\":{\"@id\":\"https:\/\/acrel.pl\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/1381afb4-7a36-4d7d-bb44-8ded3d5437e6.png\",\"datePublished\":\"2026-10-13T08:55:37+00:00\",\"dateModified\":\"2026-10-27T02:11:55+00:00\",\"description\":\"Acrel ALP220-EF Earth Fault Overcurrent Relay is designed for low-voltage applications (up to 380 V) where it is necessary to monitor the system's ground current and provide protection when the ground current exceeds the permissible limit. This relay features an LCD display, Modbus-RTU communication capability, system current measurement, three- phase current overcurrent protection, ground current overcurrent protection, residual current measurement, residual current overcurrent protection, fault logging, and event logging functions.\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/#primaryimage\",\"url\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/1381afb4-7a36-4d7d-bb44-8ded3d5437e6.png\",\"contentUrl\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/1381afb4-7a36-4d7d-bb44-8ded3d5437e6.png\",\"width\":710,\"height\":634},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/acrel.pl\/#website\",\"url\":\"https:\/\/acrel.pl\/\",\"name\":\"ACREL\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/acrel.pl\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Acrel\u00a0ALP220-EF Low-voltage Earth Fault Relay - ACREL","description":"Acrel ALP220-EF Earth Fault Overcurrent Relay is designed for low-voltage applications (up to 380 V) where it is necessary to monitor the system's ground current and provide protection when the ground current exceeds the permissible limit. This relay features an LCD display, Modbus-RTU communication capability, system current measurement, three- phase current overcurrent protection, ground current overcurrent protection, residual current measurement, residual current overcurrent protection, fault logging, and event logging functions.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/acrel.pl\/ru\/product\/medical-isolation-power-panels\/","og_locale":"en_US","og_type":"article","og_title":"Acrel\u00a0ALP220-EF Low-voltage Earth Fault Relay - ACREL","og_description":"Acrel ALP220-EF Earth Fault Overcurrent Relay is designed for low-voltage applications (up to 380 V) where it is necessary to monitor the system's ground current and provide protection when the ground current exceeds the permissible limit. This relay features an LCD display, Modbus-RTU communication capability, system current measurement, three- phase current overcurrent protection, ground current overcurrent protection, residual current measurement, residual current overcurrent protection, fault logging, and event logging functions.","og_url":"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/","og_site_name":"ACREL","article_modified_time":"2026-10-27T02:11:55+00:00","og_image":[{"width":710,"height":634,"url":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/1381afb4-7a36-4d7d-bb44-8ded3d5437e6.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/","url":"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/","name":"Acrel\u00a0ALP220-EF Low-voltage Earth Fault Relay - ACREL","isPartOf":{"@id":"https:\/\/acrel.pl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/#primaryimage"},"image":{"@id":"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/#primaryimage"},"thumbnailUrl":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/1381afb4-7a36-4d7d-bb44-8ded3d5437e6.png","datePublished":"2026-10-13T08:55:37+00:00","dateModified":"2026-10-27T02:11:55+00:00","description":"Acrel ALP220-EF Earth Fault Overcurrent Relay is designed for low-voltage applications (up to 380 V) where it is necessary to monitor the system's ground current and provide protection when the ground current exceeds the permissible limit. This relay features an LCD display, Modbus-RTU communication capability, system current measurement, three- phase current overcurrent protection, ground current overcurrent protection, residual current measurement, residual current overcurrent protection, fault logging, and event logging functions.","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/acrel.pl\/product\/medical-isolation-power-panels\/#primaryimage","url":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/1381afb4-7a36-4d7d-bb44-8ded3d5437e6.png","contentUrl":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/1381afb4-7a36-4d7d-bb44-8ded3d5437e6.png","width":710,"height":634},{"@type":"WebSite","@id":"https:\/\/acrel.pl\/#website","url":"https:\/\/acrel.pl\/","name":"ACREL","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/acrel.pl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/product\/3643","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/media\/4693"}],"wp:attachment":[{"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/media?parent=3643"}],"wp:term":[{"taxonomy":"productcat","embeddable":true,"href":"https:\/\/acrel.pl\/ru\/wp-json\/wp\/v2\/productcat?post=3643"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}