Acrel loT platform enables widespread connectivity with various devices and sensors, offering functions such as remote data collection, status monitoring, and controlling. it supports flexible networking solutions, including both centralized and distributed architecture, integrating data streams for clients and creating value.
Main Dashboard:
Provide device status, device alarm information and energy statistics data,supports two theme colors, light and dark, and supports multiple languages.
Power Monitoring:
Show all of the energy meter(gateway) real time data access in.
Distribution Diagram:
Displays the primary power distribution diagram. It is necessary to draw the distribution diagram before viewing the power distribution diagram.
Parameters Report:
Displays the electrical parameter report of the project. Users can view the electrical parameter report of the equipment in each area, Also the corresponding data by switching the time and adjusting the electrical parameter display.
Energy Management:
YoY analysis:YoY analysis (The year-on-year analysis) can count the total energy consumption of a certain type of energy consumption for a project. According to the project name, energy category, and year, users can view the energy consumption data and graphs of the project.
MoM analysis:MoM analysis(The month-on-month analysis) can view the energy consumption and the corresponding chain energy consumption by daily and monthly, and display them in the form of reports.
Energy Report:The energy report mainly counts the daily, monthly and annual reports of energy consumption, and supports excel export
Multiple Rate Report:The multi-rate report mainly counts the peak, peak, flat and valley electric energy and electricity charges,but The metering device need to support the statistical function by time period.
Energy Rank:The energy rank can rank the energy consumption of the rooms, and display in the form of graphs and report
Energy Flow:The energy flow shows the flow diagram of the energy consumption of each energy type. Users can view the energy flow according to the project, start time and end time.
Alarm Management:
Once the device occurs some alarms, the relevant personnel can check the alarm information in time and make corresponding treatment
Alarm Information: displays the alarm information of all devices under the associated project. You can search for the corresponding alarm records according to the alarm type, work order status, project name, area location, and time
Alarm dispatch: displays the alarm records that have not been distributed. You can search for the corresponding alarm records according to the alarm type, project name, area location, and time
Alarm Handling:displays the alarms to be processed, and you can search the corresponding alarm records according to the alarm type, project name, area location, and time
Wireless temperature:
Cabinet temperature: show the Cabinet temperature,The temperature collector can be installed in the cabinet.
Cable temperature: show Cable temperature,The temperature collector can be fixed on the cable.
Energy Quality:
Harmonic Monitoring: displays the harmonic monitoring data in chart form and data form. Different phases voltage and current harmonics will be displayed in the form of graphs or data lists
Three Phase Unbalance: include three-phase voltage unbalance degree and three-phase current unbalance degree. It supports to view the graph of three-phase current and three-phase voltage of the day, and corresponds to the unbalance degree of three-phase current and three-phase voltage
Demand Analysis:
Demand analysis includes maximum demand reports and demand monitoring functions.
Maximum Demand Report: displays the monthly maximum demand. can search the monthly maximum demand and demand time point within the time period according to the query conditions
Demand Monitoring: show the daily demand of the detector, which can be switched between graphs and data
PV:
PV Site Dashboard: shows the site information.include:Power station information, environmental information, peak information and statistical information、Increase the daily power curve to show the maximum power and irradiance.
Photovoltaic Statistics: displays the statistics of photovoltaic power generation、The current generation capacity and the previous generation capacity of the power station can be calculated by day, month and year.
Inverter Monitor: displays real-time data of DC side and AC side、historical data of DC and AC measurements、Displays the generation power curve by day, month and year.
Operation Management
Inspection Plan: displays the created inspection plan. The default is to display the inspection plan of the current month. can search data at other times by switching the date. It supports the activation, addition, modification and deletion of the inspection plan, as shown in ,When the inspection plan is not enabled, the system will not generate inspection records related to the inspection plan.
Inspection Record: displays the inspection records of the current month. can search the inspection record according to the three states of non-inspection, normal, and inspection
Meter Status: can search the all meters’ communication status by the project name, gateway identification number, meter address, meter model, and meter status
Gateway Status: can search all the gateways’ communication status by the project name, gateway identification number, and gateway status
User Report:
The user report can generate project overview, energy consumption analysis, energy consumption ranking, financial statements, and financial details according to the project and time period, and supports the printing function