AMC16Z-FDK24/48 DC multi circuits energy meter is independently designed to meet the needs of the increasingly high precision power distribution management requirements of the data center. It is suitable for carious all-round inrelligent monitoring of terminal distribution equipment.
●24 channels of each circuit of A+B
●Independent 2 circuits the outgoing current
●Active power, active power, reactive power
●2-31st harmonic
●48DI
●1 RS485 communication
Technical parameters | AMC16Z-FDK24 | AMC16Z-FDK48 |
Measured parameter | Voltage,current,power,electrical energy,switching state | |
Bus voltage | Ratetd | 48VDC,240VDC,336VDC |
Currentoutcoming line circuit | Ratetd | 5V (Hall sensor,external power supply ±12V) |
Measurement precision | Outgoing line | Voltage/current level 0.5,power/electric energy level 1 |
Auxiliary power | Get power supply from AMC16Z-ZD | |
Environment | Work: -15℃ ~ 55℃ Storage: -25℃ ~ 70℃ Relative humidity ≤93% | |
Communication | RS485/Modbus-RTU | |
Installation | DIN35mm guide rail or baseplate mounted | |
Protection level | IP20 | |
Security | All terminals and the insulation resistance between the conductive piecesnot below 100 m Ω |
Type Model | Function description |
AMC16Z-ZA | Monitor the full power parameters of A+B double-way three-phase AC incomingcircuit,6-way switch state monitoring,2-way alarm output,2-way leakagemonitoring, 1-way temperature and humidity detection,1-way RS485communication, and phase-sequence detection. |
AMC16Z-FA | Monitor the full power parameters of 24 branches of A+B double-way ACoutgoing line,1-way RS485 communication and phase adjustment. |
AMC16Z-FAK24 | Monitor the full power parameters and switch state of 24 branches of A+Bdouble-way AC outgoing line,1-way RS485 communication and phaseadjustment. |
AMC16Z-FAK48 | Monitor the full power parameters and switch state of 48 branches of A+Bdouble-way AC outgoing line,1-way RS485 communication and phaseadjustment. |
AMC16Z-KA | Wet contact,monitoring A+B total 48 branch switch state,1-way RS485communication. |
AMC16Z-KD | Dry contact,monitoring A+B total 48 branch switch state,1-way RS485communication. |
AMC16Z-AC220V | AC220V extended power supply,and use when the monitoring circuit is beyond 96 branches of A+B |
AMC100-ZA | Monitoring the full power parameters of the A+B dual three-phase AC incoming circuit, 8 switching status inputs, 4 switching status outputs, 2 leakage monitoring, 1 temperature and humidity detection, 3 RS485 communications |
AMC100-FAK30 | Monitor the full power parameters and switch status of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication |
AMC100-FAK48 | Monitor the full power parameters and switch status of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication |
AMC100-FA30 | Monitor the full power parameters of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication |
AMC100-FA48 | Monitor the full power parameters of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication |
AMC100-KA30 | Wet contact, monitor the switching status of 30 branches A+B, 1 RS485 communication |
AMC100-KA48 | Wet contact, monitor the switching status of 48 branches A+B, 1 RS485 communication |
AMC100-KD30 | Dry contact, monitor the switching status of 30 branches A+B, 1 RS485 communication |
AMC100-KD48 | Dry contact, monitor the switching status of 48 branches A+B, 1 RS485 communication |
AMC100-FT30 | 1 way RS485 communication, 30 way temperature measurement |
AMC100-FT48 | 1 way RS485 communication, 48 way temperature measurement |