{"id":4221,"date":"2026-10-14T07:44:18","date_gmt":"2026-10-14T07:44:18","guid":{"rendered":"https:\/\/acrel.pl\/?post_type=product&p=4221"},"modified":"2026-10-14T07:44:24","modified_gmt":"2026-10-14T07:44:24","slug":"asj10l-ld1a-leakage-current-protection-relay","status":"publish","type":"product","link":"https:\/\/acrel.pl\/pl\/product\/asj10l-ld1a-leakage-current-protection-relay\/","title":{"rendered":"ASJ10L-LD1A Leakage Current Protection Relay"},"content":{"rendered":"\n
ASJ Series of action relay of after-current, low-voltage circuit break or low-voltage contactor can be made up for combined after-current production device, which is mainly applied for the TT and TN system distributing circuit with the alternating current 50Hz, the rated voltage 400V or below.
ASJ Series of action relay of after-current is applied in the earth fault protection for the electric circuit, so as to prevent the equipment damage and the fire accident of electric equipment caused by the ground fault current, moreover, it also can provide indirect contact protection against the electric shock risk.<\/p>\n\n\n\n
<\/figure>\n\n\n\nFunction<\/strong><\/h2>\n\n\n\n
Relay Type<\/td> Panel size (mm)<\/td> Shell size (mm)<\/td> Hole size(mm)<\/td><\/tr> ASJ20-LD1CASJ20-LD1A<\/td> 48\u00d748( width by height)<\/td> 43.8\u00d743.8\u00d7100\uff08width by height by depth\uff09<\/td> 45\u00d745\uff08width by height\uff09<\/td><\/tr> ASJ10-LD1CASJ10-LD1AASJ10L-LD1A<\/td> 85\u00d754\u00d764\uff08length by width by height\uff09<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n
<\/figure>\n\n\n\nTechnical Parameter<\/h2>\n\n\n\n
Input<\/td> Rated residualoperated current I\u25b3n<\/td> 0.03, 0.05, 0.1, 0.3, 0.5, 1, 3, 5, 10, 30(A)<\/td><\/tr> Limitation non\u0002 driving time<\/td> 0,0.06, 0.1, 0.2, 0.3, 0.5, 0.8, 1, 4, 10(S)<\/td><\/tr> Rated non-action residual current<\/td> 50%I\u25b3n<\/td><\/tr> Frequency<\/td> 50Hz\u00b15Hz<\/td><\/tr> Tripping accuracy<\/td> -20% ~ -10%I\u25b3n<\/td><\/tr> Output<\/td> Output mode<\/td> 1 normal changeover contact<\/td><\/tr> Contact capacity<\/td> AL1: 8A 250VAC 5A 30VDCAL2: 6A 250VAC 5A 30VDC<\/td><\/tr> Reset mode<\/td> Local, remote, automatic<\/td><\/tr> Auxiliary power supply<\/td> Voltage range<\/td> AC\/DC85~270V<\/td><\/tr> Power consumption<\/td> \u22645W<\/td><\/tr> Power frequency withstand voltage<\/td> The effective value of alternating current between the power supply, input and output: 2kV\/1min<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n Dimension<\/strong><\/h2>\n\n\n\n


Wiring<\/strong><\/h2>\n\n\n\n
<\/figure>\n\n\n\nTypical Connection<\/strong><\/h2>\n\n\n\n

<\/figure>\n","protected":false},"excerpt":{"rendered":"\u25cf The measurement of AC type after-current;\n\u25cf The streamer display of current percentage;\n\u25cf The setting of rated residual action current;\n\u25cf The setting of non-driving time of limitation;\n\u25cf Two-pair relay output;\n\u25cf Possessing the function of on-the-spot and long-distance testing and resetting.","protected":false},"featured_media":4225,"template":"","productcat":[6,41],"class_list":["post-4221","product","type-product","status-publish","has-post-thumbnail","hentry","productcat-power-protection","productcat-leakage-current-protection-relay"],"yoast_head":"\n