{"id":4090,"date":"2026-10-13T08:29:21","date_gmt":"2026-10-13T08:29:21","guid":{"rendered":"https:\/\/acrel.pl\/?post_type=product&#038;p=4090"},"modified":"2026-10-13T08:29:28","modified_gmt":"2026-10-13T08:29:28","slug":"alp500-low-voltage-protection-and-control-relay","status":"publish","type":"product","link":"https:\/\/acrel.pl\/pl\/product\/alp500-low-voltage-protection-and-control-relay\/","title":{"rendered":"ALP500 Low Voltage Protection and Control Relay"},"content":{"rendered":"<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>General<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p>Acrel ALP500 low-voltage protection measurement and control device (hereinafter referred to as low-voltage protection device) is suitable for low-voltage power distribution circuit with rated voltage to AC660V, integrating power monitoring, feeder protection, opening and closing control, communication networking, node temperature measurement, operation and maintenance management and other functions.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>It has various protection functions such as inverse time overcurrent, three-stage overcurrent, overpower, zero sequence overcurrent, undervoltage, overvoltage, unbalance (voltage, current), neutral line overcurrent, and leakage current. Different communication modules can be selected to meet the needs of on-site communication.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p><br>The product adopts embedded installation and consists of a main body, a transformer and optional functional modules.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Function<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p>1) Dynamically adjusts protection strategy based on cable heating characteristics to prevent overload burnout;<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>2) Zero-sequence\/leakage current protection;<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>3) Accurately detects grounding faults to prevent electric shock and fire;<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>4) Temperature-linked protection;<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>5) Equipped with wired\/wireless temperature measurement modules, it monitors busbar and node temperatures in real time, providing automatic over-temperature warnings;<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>6) Voltage\/current imbalance protection;<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>7) Promptly detects three-phase imbalances to reduce equipment losses.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Additional Function<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Additional Functions<\/td><td class=\"has-text-align-center\" data-align=\"center\">Code Name<\/td><td class=\"has-text-align-center\" data-align=\"center\">Additional Functions<\/td><td class=\"has-text-align-center\" data-align=\"center\">Code Name<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">2-63rd harmonic voltage and current<\/td><td class=\"has-text-align-center\" data-align=\"center\">H<\/td><td class=\"has-text-align-center\" data-align=\"center\">Waveform record<\/td><td class=\"has-text-align-center\" data-align=\"center\">WR<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"5\">Communication Module(Choose one)<\/td><td class=\"has-text-align-center\" data-align=\"center\">1*Profibus DPV0 Communication<\/td><td class=\"has-text-align-center\" data-align=\"center\">CP<\/td><td class=\"has-text-align-center\" data-align=\"center\">Leakage protection<\/td><td class=\"has-text-align-center\" data-align=\"center\">L<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">2*Profibus DPV0 Communication<\/td><td class=\"has-text-align-center\" data-align=\"center\">2CP<\/td><td class=\"has-text-align-center\" data-align=\"center\">Metering module<\/td><td class=\"has-text-align-center\" data-align=\"center\">S<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Ethernet Communication (Modbus-TCP protocol)<\/td><td class=\"has-text-align-center\" data-align=\"center\">MCE<\/td><td class=\"has-text-align-center\" data-align=\"center\">1*4-20mA Analog output<\/td><td class=\"has-text-align-center\" data-align=\"center\">M1<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">4G<\/td><td class=\"has-text-align-center\" data-align=\"center\">4G<\/td><td class=\"has-text-align-center\" data-align=\"center\">2*4-20mA Analog output<\/td><td class=\"has-text-align-center\" data-align=\"center\">M2<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Lora<\/td><td class=\"has-text-align-center\" data-align=\"center\">LORA<\/td><td class=\"has-text-align-center\" data-align=\"center\">Switch module<\/td><td class=\"has-text-align-center\" data-align=\"center\">MD<\/td><\/tr><\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Technical Parameter<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Technical Parameters<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Technical Indicators<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Auxiliary Power<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Support AC 85-265V\/DC 100-300V, Wide range power input<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Rated Voltage<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">AC 380V \/ 660V\uff0c50Hz \/ 60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\" rowspan=\"4\">Rated Current<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 (0.5A-6300A)<\/td><td class=\"has-text-align-center\" data-align=\"center\">XXX\/1A Transformer with external CT<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">5 (0.5A-6300A)<\/td><td class=\"has-text-align-center\" data-align=\"center\">XXX\/5A Transformer with external CT<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">25 (6A-25A)<\/td><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">external current transformer<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">100 (25A-100A)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"6\">Accuracy<\/td><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"3\">ProtectionAccuracy<\/td><td class=\"has-text-align-center\" data-align=\"center\">3-phase Current<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.0 Class<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">3-phase Voltage<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.5 Class<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Power, Electrical Energy<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.5 Class<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"3\">MeasuringAccuracy<\/td><td class=\"has-text-align-center\" data-align=\"center\">3-phase Current\u3001Voltage<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.5 Class<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Active Power, Electrical Energy<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.5 Class<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Reactive Power, Electrical Energy<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.0 Class<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\" rowspan=\"2\">Relay OutputContact Capacity<\/td><td class=\"has-text-align-center\" data-align=\"center\">Standard configuration 4 channels<\/td><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">Resistive load\u3001AC250V\/10A<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Optional 3 channels<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\" rowspan=\"2\">Digital Input<\/td><td class=\"has-text-align-center\" data-align=\"center\">Standard configuration 4 channels passive dry junction<\/td><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">Optional active DC110V\u3001DC220V\u3001AC220V input<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Optional10 channels passive dry junction<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\" rowspan=\"6\">Communication<\/td><td class=\"has-text-align-center\" data-align=\"center\">Standard configuration<\/td><td class=\"has-text-align-center\" data-align=\"center\">2*MODBUS RTU Communication<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"5\">Optional (Choose one)<\/td><td class=\"has-text-align-center\" data-align=\"center\">1*MODBUS-TCP<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">1*PROFIBUS-DPV0<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">2*PROFIBUS-DPV0<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">1*4G Communication<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">1*Lora Communication<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\" rowspan=\"4\">Application Environment<\/td><td class=\"has-text-align-center\" data-align=\"center\">Working Temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\">-10\u00baC\uff5e55\u00baC<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Storage temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\">-25\u00baC\uff5e70\u00baC<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Relative humidity<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u226495%, No condensation, No corrosive gas<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Altitude<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u22642000m<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Pollution Level<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">3 Class<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Protection Grade<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Main Body IP54, Additional function modules IP20<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Installation Type<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">III Class<\/td><\/tr><\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Dimension<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4096,\"width\":\"500px\",\"height\":\"auto\",\"aspectRatio\":\"1.272264631043257\",\"align\":\"center\"} -->\n<figure class=\"wp-block-image aligncenter is-resized\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20260818065005_69199.png\" alt=\"\" class=\"wp-image-4096\" style=\"aspect-ratio:1.272264631043257;width:500px;height:auto\" title=\"\"\/><figcaption class=\"wp-element-caption\"><strong>Dimension of current transformer<\/strong><\/figcaption><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:image {\"id\":4093,\"sizeSlug\":\"full\",\"linkDestination\":\"none\",\"align\":\"center\"} -->\n<figure class=\"wp-block-image aligncenter size-full\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/0558a87d-2348-4322-a3ba-edaf7ae0d0fa.png\" alt=\"\" class=\"wp-image-4093\"\/><figcaption class=\"wp-element-caption\"><strong>Dimension of main body &amp; additional functional module<\/strong><\/figcaption><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Typical Connection<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4095} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20260818064023_15848.png\" alt=\"\" class=\"wp-image-4095\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Application<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":4097} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/20211119060848_89118.jpg\" alt=\"\" class=\"wp-image-4097\"\/><\/figure>\n<!-- \/wp:image -->","protected":false},"excerpt":{"rendered":"\u25cf Integrate leakage, overload and earth fault protection\n\u25cf Comprehensive protection functions\n\u25cf High accuracy energy metering\n\u25cf Support Modbus-RTU\u3001Modbus-TCP\u3001Profibus-DP Communication\n\u25cf 2nd~63rd harmonic measurement\n\u25cf Wired Temperature measurement - PT100\u3001PT1000\u3001NTC; Wireless Temperature measurement - ATE100\u3001ATE200\u3001ATE400\n\u25cf Suitable for AC 690V and below low-voltage switchgear, distribution panels and feeder circuits.","protected":false},"featured_media":4092,"template":"","productcat":[6,44],"class_list":["post-4090","product","type-product","status-publish","has-post-thumbnail","hentry","productcat-power-protection","productcat-motor-protection"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ALP500 Low Voltage Protection and Control Relay - ACREL<\/title>\n<meta name=\"description\" content=\"Acrel ALP500 low-voltage protection measurement and control device (hereinafter referred to as low-voltage protection device) is suitable for low-voltage power distribution circuit with rated voltage to AC660V , integrating power monitoring, feeder protection, opening and closing control, communication networking, node temperature measurement, operation and maintenance management and other functions.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/acrel.pl\/pl\/ru\/product\/alp500-low-voltage-protection-and-control-relay\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ALP500 Low Voltage Protection and Control Relay - ACREL\" \/>\n<meta property=\"og:description\" content=\"Acrel ALP500 low-voltage protection measurement and control device (hereinafter referred to as low-voltage protection device) is suitable for low-voltage power distribution circuit with rated voltage to AC660V , integrating power monitoring, feeder protection, opening and closing control, communication networking, node temperature measurement, operation and maintenance management and other functions.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/acrel.pl\/ru\/product\/alp500-low-voltage-protection-and-control-relay\/\" \/>\n<meta property=\"og:site_name\" content=\"ACREL\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-13T08:29:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/ALP500\u4e3b\u4f53\u6b63\u9762-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"2560\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/acrel.pl\/ru\/product\/alp500-low-voltage-protection-and-control-relay\/\",\"url\":\"https:\/\/acrel.pl\/ru\/product\/alp500-low-voltage-protection-and-control-relay\/\",\"name\":\"ALP500 Low Voltage Protection and Control Relay - ACREL\",\"isPartOf\":{\"@id\":\"https:\/\/acrel.pl\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/acrel.pl\/ru\/product\/alp500-low-voltage-protection-and-control-relay\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/acrel.pl\/ru\/product\/alp500-low-voltage-protection-and-control-relay\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/ALP500\u4e3b\u4f53\u6b63\u9762-scaled.jpg\",\"datePublished\":\"2026-10-13T08:29:21+00:00\",\"dateModified\":\"2026-10-13T08:29:28+00:00\",\"description\":\"Acrel ALP500 low-voltage protection measurement and control device (hereinafter referred to as low-voltage protection device) is suitable for low-voltage power distribution circuit with rated voltage to AC660V , integrating power monitoring, feeder protection, opening and closing control, communication networking, node temperature measurement, operation and maintenance management and other functions.\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/acrel.pl\/ru\/product\/alp500-low-voltage-protection-and-control-relay\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/acrel.pl\/ru\/product\/alp500-low-voltage-protection-and-control-relay\/#primaryimage\",\"url\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/ALP500\u4e3b\u4f53\u6b63\u9762-scaled.jpg\",\"contentUrl\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/ALP500\u4e3b\u4f53\u6b63\u9762-scaled.jpg\",\"width\":2560,\"height\":2560},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/acrel.pl\/#website\",\"url\":\"https:\/\/acrel.pl\/\",\"name\":\"ACREL\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/acrel.pl\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ALP500 Low Voltage Protection and Control Relay - ACREL","description":"Acrel ALP500 low-voltage protection measurement and control device (hereinafter referred to as low-voltage protection device) is suitable for low-voltage power distribution circuit with rated voltage to AC660V , integrating power monitoring, feeder protection, opening and closing control, communication networking, node temperature measurement, operation and maintenance management and other functions.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/acrel.pl\/pl\/ru\/product\/alp500-low-voltage-protection-and-control-relay\/","og_locale":"en_US","og_type":"article","og_title":"ALP500 Low Voltage Protection and Control Relay - ACREL","og_description":"Acrel ALP500 low-voltage protection measurement and control device (hereinafter referred to as low-voltage protection device) is suitable for low-voltage power distribution circuit with rated voltage to AC660V , integrating power monitoring, feeder protection, opening and closing control, communication networking, node temperature measurement, operation and maintenance management and other functions.","og_url":"https:\/\/acrel.pl\/ru\/product\/alp500-low-voltage-protection-and-control-relay\/","og_site_name":"ACREL","article_modified_time":"2026-10-13T08:29:28+00:00","og_image":[{"width":2560,"height":2560,"url":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/ALP500\u4e3b\u4f53\u6b63\u9762-scaled.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/acrel.pl\/ru\/product\/alp500-low-voltage-protection-and-control-relay\/","url":"https:\/\/acrel.pl\/ru\/product\/alp500-low-voltage-protection-and-control-relay\/","name":"ALP500 Low Voltage Protection and Control Relay - ACREL","isPartOf":{"@id":"https:\/\/acrel.pl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/acrel.pl\/ru\/product\/alp500-low-voltage-protection-and-control-relay\/#primaryimage"},"image":{"@id":"https:\/\/acrel.pl\/ru\/product\/alp500-low-voltage-protection-and-control-relay\/#primaryimage"},"thumbnailUrl":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/ALP500\u4e3b\u4f53\u6b63\u9762-scaled.jpg","datePublished":"2026-10-13T08:29:21+00:00","dateModified":"2026-10-13T08:29:28+00:00","description":"Acrel ALP500 low-voltage protection measurement and control device (hereinafter referred to as low-voltage protection device) is suitable for low-voltage power distribution circuit with rated voltage to AC660V , integrating power monitoring, feeder protection, opening and closing control, communication networking, node temperature measurement, operation and maintenance management and other functions.","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/acrel.pl\/ru\/product\/alp500-low-voltage-protection-and-control-relay\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/acrel.pl\/ru\/product\/alp500-low-voltage-protection-and-control-relay\/#primaryimage","url":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/ALP500\u4e3b\u4f53\u6b63\u9762-scaled.jpg","contentUrl":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/10\/ALP500\u4e3b\u4f53\u6b63\u9762-scaled.jpg","width":2560,"height":2560},{"@type":"WebSite","@id":"https:\/\/acrel.pl\/#website","url":"https:\/\/acrel.pl\/","name":"ACREL","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/acrel.pl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/product\/4090","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/media\/4092"}],"wp:attachment":[{"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/media?parent=4090"}],"wp:term":[{"taxonomy":"productcat","embeddable":true,"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/productcat?post=4090"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}