{"id":3872,"date":"2026-09-17T05:56:47","date_gmt":"2026-09-17T05:56:47","guid":{"rendered":"https:\/\/acrel.pl\/?post_type=product&#038;p=3872"},"modified":"2026-09-17T06:21:13","modified_gmt":"2026-09-17T06:21:13","slug":"bd-ai-ac-current-transducer","status":"publish","type":"product","link":"https:\/\/acrel.pl\/pl\/product\/bd-ai-ac-current-transducer\/","title":{"rendered":"BD-AI AC Current Transducer"},"content":{"rendered":"<!-- wp:paragraph -->\n<p>\u25cf Model: BD-AI \/ BD-AI2\u00a0Current Transducer<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf AC current input: 0-1A or 0-5A<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf Overload: 1.2 times of rated value<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf Analog Output: DC0-5V, DC0-10V, DC0-20mA and DC4-20mA<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf Power supply: AC85-265V, DC24V or DC48V<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf Isolation withstand voltage, strong anti-interference, load bearing capacity<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf Applied in data center, buillding, industry, seaport, etc.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>\u25cf Connect with the pointer table, digital meters, also can connected with automatic control devices (eg PLC), a variety of A \/ D converter, and the computer system<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Product Selection<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Current Transducer<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:image {\"id\":3874} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/20211112112227_71904.png\" alt=\"\" class=\"wp-image-3874\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:paragraph -->\n<p><strong>Voltage Transducer<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:image {\"id\":3877} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/20211112112248_55207.png\" alt=\"\" class=\"wp-image-3877\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong><\/strong><strong>Specification<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\"><strong>Type<\/strong><strong><\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>BD-DI<\/strong><strong>BD-DV<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>BD-AI<\/strong><strong>BD-AV<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>BD-3I3<\/strong><strong>BD-3V3<\/strong><strong>BD-4V3<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>BD-3P<\/strong><strong>BD-3Q<\/strong><strong>BD-3P\/Q\/I<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>BD-4P<\/strong><strong>BD-4Q<\/strong><strong>BD-4P\/Q\/I<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>BD-3E<\/strong><strong>BD-4E<\/strong><strong>BD-4EA<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>BD-PF<\/strong><strong>BD-F<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Precision grade<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"7\">0.5<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Input<\/td><td class=\"has-text-align-center\" data-align=\"center\">Signal<\/td><td class=\"has-text-align-center\" data-align=\"center\">DC 4~20mA, 0~20mADC 0~10V,&nbsp;0~75mVDC 0~300V<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">AC 0~1A\u30010~5AAC 0~120V\u30010~300V\u30010~500V<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"4\">AC 1A\u30015AAC 100V\u3001220V\u3001380V<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Overload<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"7\">Current:1.2 times everlasting\uff0c10 times\/1sVoltage\uff1a1.2 times everlasting\uff0c2times\/1s<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Frequency<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"7\">45Hz~65Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Output<\/td><td class=\"has-text-align-center\" data-align=\"center\">Signal<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"7\">DC 4~20mA\u30010~20mA\u30010~5V\u30010~10V<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Load<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"7\">Current Output\u2264600\u03a9&nbsp;Voltage Output\u22651000\u03a9<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Selected function<\/td><td class=\"has-text-align-center\" data-align=\"center\">\uff0f<\/td><td class=\"has-text-align-center\" data-align=\"center\">RS485<\/td><td class=\"has-text-align-center\" data-align=\"center\">\uff0f<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"4\">RS485 communication<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Power supply<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"7\">AC 85V~265V\/DC 100V~350V&nbsp;Or DC24V or DC48V<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Temperature drift coefficient<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"7\">Class 0.5 \u2264200ppm\/\u2103\uff0cclass 0.2\u2264100ppm\/\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Response time<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"7\">&lt;400ms<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Insulation resistance<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"7\">\u2265100M\u03a9<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Power frequency withstand voltage<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"7\">the value of alternating current between the power supply, input and output: 2kV\/1min<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Ambient conditions<\/td><td class=\"has-text-align-center\" data-align=\"center\">Temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"7\">operating temperature: -10\u2103 ~ +55\u2103storage temperature: -25\u2103 ~ +70\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Humidity<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"7\">\u226495%RH, no dew, no aggressive gas<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">Altitude<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"7\">\u22642500m<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Installation method<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"7\">TS35mm rail&nbsp;designed&nbsp;or screw<\/td><\/tr><\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Dimension<\/strong><strong><strong>Spec. and size (unit\uff1amm)<\/strong><\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":3876} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/20211112111912_69923.png\" alt=\"\" class=\"wp-image-3876\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong><strong>Wiring<\/strong><\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":3875} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/20211112111949_67161.png\" alt=\"\" class=\"wp-image-3875\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Application<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":3873} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/20211112110345_17094.png\" alt=\"\" class=\"wp-image-3873\"\/><\/figure>\n<!-- \/wp:image -->","protected":false},"excerpt":{"rendered":"<p>\u25cf Model: BD-AI \/ BD-AI2\u00a0Current Transducer \u25cf AC current input: 0-1A or 0-5A \u25cf Overload: 1.2 times of rated value \u25cf Analog Output: DC0-5V, DC0-10V, DC0-20mA and DC4-20mA \u25cf Power supply: AC85-265V, DC24V or DC48V \u25cf Isolation withstand voltage, strong anti-interference, load bearing capacity \u25cf Applied in data center, buillding, industry, seaport, etc. \u25cf Connect [&hellip;]<\/p>\n","protected":false},"featured_media":3878,"template":"","productcat":[9,64],"class_list":["post-3872","product","type-product","status-publish","has-post-thumbnail","hentry","productcat-power-sensor","productcat-power-transmitter"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>BD-AI AC Current Transducer - ACREL<\/title>\n<meta name=\"description\" content=\"BD series electric transducer is a kind of device which can isolate and transmit electric parameters such as current,voltage frequency, power, power factor or temperature, resistance and so on non-electrical parameters, into linear DC analog signal or digital signal. They can directly connect with the pointer table, digital meters, also can connected with automatic control devices (eg PLC), a variety of A \/ D converter, and the computer system.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/acrel.pl\/pl\/ru\/product\/bd-ai-ac-current-transducer\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"BD-AI AC Current Transducer - ACREL\" \/>\n<meta property=\"og:description\" content=\"BD series electric transducer is a kind of device which can isolate and transmit electric parameters such as current,voltage frequency, power, power factor or temperature, resistance and so on non-electrical parameters, into linear DC analog signal or digital signal. They can directly connect with the pointer table, digital meters, also can connected with automatic control devices (eg PLC), a variety of A \/ D converter, and the computer system.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/acrel.pl\/ru\/product\/bd-ai-ac-current-transducer\/\" \/>\n<meta property=\"og:site_name\" content=\"ACREL\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-17T06:21:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/BD-AI.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/acrel.pl\/ru\/product\/bd-ai-ac-current-transducer\/\",\"url\":\"https:\/\/acrel.pl\/ru\/product\/bd-ai-ac-current-transducer\/\",\"name\":\"BD-AI AC Current Transducer - ACREL\",\"isPartOf\":{\"@id\":\"https:\/\/acrel.pl\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/acrel.pl\/ru\/product\/bd-ai-ac-current-transducer\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/acrel.pl\/ru\/product\/bd-ai-ac-current-transducer\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/BD-AI.webp\",\"datePublished\":\"2026-09-17T05:56:47+00:00\",\"dateModified\":\"2026-09-17T06:21:13+00:00\",\"description\":\"BD series electric transducer is a kind of device which can isolate and transmit electric parameters such as current,voltage frequency, power, power factor or temperature, resistance and so on non-electrical parameters, into linear DC analog signal or digital signal. They can directly connect with the pointer table, digital meters, also can connected with automatic control devices (eg PLC), a variety of A \/ D converter, and the computer system.\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/acrel.pl\/ru\/product\/bd-ai-ac-current-transducer\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/acrel.pl\/ru\/product\/bd-ai-ac-current-transducer\/#primaryimage\",\"url\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/BD-AI.webp\",\"contentUrl\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/BD-AI.webp\",\"width\":800,\"height\":800},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/acrel.pl\/#website\",\"url\":\"https:\/\/acrel.pl\/\",\"name\":\"ACREL\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/acrel.pl\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"BD-AI AC Current Transducer - ACREL","description":"BD series electric transducer is a kind of device which can isolate and transmit electric parameters such as current,voltage frequency, power, power factor or temperature, resistance and so on non-electrical parameters, into linear DC analog signal or digital signal. They can directly connect with the pointer table, digital meters, also can connected with automatic control devices (eg PLC), a variety of A \/ D converter, and the computer system.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/acrel.pl\/pl\/ru\/product\/bd-ai-ac-current-transducer\/","og_locale":"en_US","og_type":"article","og_title":"BD-AI AC Current Transducer - ACREL","og_description":"BD series electric transducer is a kind of device which can isolate and transmit electric parameters such as current,voltage frequency, power, power factor or temperature, resistance and so on non-electrical parameters, into linear DC analog signal or digital signal. They can directly connect with the pointer table, digital meters, also can connected with automatic control devices (eg PLC), a variety of A \/ D converter, and the computer system.","og_url":"https:\/\/acrel.pl\/ru\/product\/bd-ai-ac-current-transducer\/","og_site_name":"ACREL","article_modified_time":"2026-09-17T06:21:13+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/BD-AI.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/acrel.pl\/ru\/product\/bd-ai-ac-current-transducer\/","url":"https:\/\/acrel.pl\/ru\/product\/bd-ai-ac-current-transducer\/","name":"BD-AI AC Current Transducer - ACREL","isPartOf":{"@id":"https:\/\/acrel.pl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/acrel.pl\/ru\/product\/bd-ai-ac-current-transducer\/#primaryimage"},"image":{"@id":"https:\/\/acrel.pl\/ru\/product\/bd-ai-ac-current-transducer\/#primaryimage"},"thumbnailUrl":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/BD-AI.webp","datePublished":"2026-09-17T05:56:47+00:00","dateModified":"2026-09-17T06:21:13+00:00","description":"BD series electric transducer is a kind of device which can isolate and transmit electric parameters such as current,voltage frequency, power, power factor or temperature, resistance and so on non-electrical parameters, into linear DC analog signal or digital signal. They can directly connect with the pointer table, digital meters, also can connected with automatic control devices (eg PLC), a variety of A \/ D converter, and the computer system.","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/acrel.pl\/ru\/product\/bd-ai-ac-current-transducer\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/acrel.pl\/ru\/product\/bd-ai-ac-current-transducer\/#primaryimage","url":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/BD-AI.webp","contentUrl":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/BD-AI.webp","width":800,"height":800},{"@type":"WebSite","@id":"https:\/\/acrel.pl\/#website","url":"https:\/\/acrel.pl\/","name":"ACREL","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/acrel.pl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/product\/3872","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/media\/3878"}],"wp:attachment":[{"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/media?parent=3872"}],"wp:term":[{"taxonomy":"productcat","embeddable":true,"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/productcat?post=3872"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}