{"id":3859,"date":"2026-09-17T02:27:35","date_gmt":"2026-09-17T02:27:35","guid":{"rendered":"https:\/\/acrel.pl\/?post_type=product&#038;p=3859"},"modified":"2026-09-17T02:34:27","modified_gmt":"2026-09-17T02:34:27","slug":"bak-series-split-core-ac-current-transducer","status":"publish","type":"product","link":"https:\/\/acrel.pl\/pl\/product\/bak-series-split-core-ac-current-transducer\/","title":{"rendered":"BAK Series Split Core AC Current Transducer"},"content":{"rendered":"<!-- wp:image {\"id\":3863,\"sizeSlug\":\"full\",\"linkDestination\":\"none\"} -->\n<figure class=\"wp-block-image size-full\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/function.png\" alt=\"\" class=\"wp-image-3863\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Technical Parameter<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:table -->\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Accuracy Class&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Class 1<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"5\"><strong>Input<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">Nominal Value<\/td><td class=\"has-text-align-center\" data-align=\"center\">BAK20-A<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Current AC 0.5A, 50A, 200A, etc. AC0\uff5e(0.5\uff5e200A)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">BAK50-AI<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Current AC 60A, 300A, 600A, etc. AC0\uff5e(60\uff5e600A)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Overload<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Continuous 1.2x, Instantaneous current 10x\/5 seconds<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Power Consumption<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">\u22641VA<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Measurement Frequency<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">45Hz\uff5e65Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"4\"><strong>Output<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Nominal Value<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">DC0\/4\uff5e20mA\uff0c0\uff5e5\/10V<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Load Resistance<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">\u2264500\u03a9 when current output, \u226510K\u03a9 when voltage output<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Communication<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">RS485 interface \/ Modbus-RTU protocol<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Digital Output(DO)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">1 relay output, Normally Open (NO) contactsCapacity 2A\/30VDC or 2A\/250VAC<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Indicators<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">2 indicators: RUN (operational status), Alarm (DO status)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Response Time<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">\u2264400ms<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\"><strong>Power Supply<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Voltage<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">DC 12V or 24V<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Power Consumption<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">\u22641W<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Insulation Resistance<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">\uff1e100M\u03a9<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Dielectric Strength<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">2.0kV\/1min, 50Hz between Input\/Output\/Power Supply<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Temperature Coefficient<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">\u2264400ppm\/\u2103 when -10\u2103\uff5e55\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"3\"><strong>Environment<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Operating: -10\u2103\uff5e+55\u2103 Storage: -25\u2103\uff5e+70\u2103<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Humidity<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">\u226493%RH, non-condensing, non-corrosive gas environment<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Altitude<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">\u22642000m<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Weight<\/td><td class=\"has-text-align-center\" data-align=\"center\">BAK20-AI approx. 242g<\/td><td class=\"has-text-align-center\" data-align=\"center\">BAK50-AI approx. 468g<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Mounting<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">TS35 rail, or fixed to cabinet with screws<\/td><\/tr><\/tbody><\/table><\/figure>\n<!-- \/wp:table -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Type Selection<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":7682} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/www.acrel-electric.uk\/uploads\/1db2b50a.jpg\" alt=\"BAK - type selection_\u526f\u672c\" class=\"wp-image-7682\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Wiring<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":7677} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/www.acrel-electric.uk\/uploads\/07d897bb.jpg\" alt=\"BAK - wiring - 1_\u526f\u672c\" class=\"wp-image-7677\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:image {\"id\":7678} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/www.acrel-electric.uk\/uploads\/1f4d1228.jpg\" alt=\"BAK - wiring - 2_\u526f\u672c\" class=\"wp-image-7678\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:paragraph -->\n<p>V+ \u2014\u2014 Power Positive (Note: Do not reverse power positive and ground)<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>DO-\u3001DO+ \u2014\u2014&nbsp;Digital Output (Switch) Interface<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>V- \u2014\u2014&nbsp; Power Ground<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>A\u3001B \u2014\u2014 RS485 Interface<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>OUT- \u2014\u2014&nbsp; Analog Output Negative<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>OUT+ \u2014\u2014&nbsp; Analog Output Positive<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>Cable is through-hole (pass-through) input<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p><strong>Indicator Definitions:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>RUN: Normal operation. When 485 communication is not connected, the RUN indicator shows green, blinking once per&nbsp;second. When the current sensor successfully connects to 485 communication, the RUN indicator blinks rapidly.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>Alarm: After the alarm function is enabled, when the input current reaches 120% of the sensor's range, the Alarm&nbsp;indicator lights red steadily and the relay output closes. When the input current drops below 110% of the sensor's range, the Alarm indicator turns off. If the alarm function is not enabled, the Alarm indicator remains off and the relay does not&nbsp;close.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p><strong>Notes:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>(1) The device uses removable terminal blocks. It is recommended to use shielded wires with a cross-sectional area of 0.75mm\u00b2 for the power, output, RS485 communication, and digital output interface sides.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>(2) Please refer to the wiring diagram on the physical housing for specific wiring connections.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Dimension<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>BAK20-AI Dimension<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:image {\"id\":7679} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/www.acrel-electric.uk\/uploads\/daef49fc.jpg\" alt=\"BAK20-AI Dimension_\u526f\u672c\" class=\"wp-image-7679\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:paragraph -->\n<p><strong>BAK50-AI Dimension<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:image {\"id\":7680} -->\n<figure class=\"wp-block-image\"><img src=\"https:\/\/www.acrel-electric.uk\/uploads\/ae002255.jpg\" alt=\"BAK50-AI Dimension_\u526f\u672c\" class=\"wp-image-7680\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><strong>Application<\/strong><\/h2>\n<!-- \/wp:heading -->\n\n<!-- wp:image {\"id\":3861,\"sizeSlug\":\"full\",\"linkDestination\":\"none\"} -->\n<figure class=\"wp-block-image size-full\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/ea2bff15-c17b-4c1f-bc81-e6ca3557ee45.png\" alt=\"\" class=\"wp-image-3861\"\/><figcaption class=\"wp-element-caption\">                  Cement Building                               Petrochemical Industry<\/figcaption><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:image {\"id\":3862,\"sizeSlug\":\"full\",\"linkDestination\":\"none\"} -->\n<figure class=\"wp-block-image size-full\"><img src=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/8699e85e-ebb3-4282-a49f-9158336501ad.png\" alt=\"\" class=\"wp-image-3862\"\/><figcaption class=\"wp-element-caption\">         Iron and Steel Metallurgy                                         Rail Traffic<\/figcaption><\/figure>\n<!-- \/wp:image -->","protected":false},"excerpt":{"rendered":"Acrel BAK Series Split-core  products utilize the principle of electromagnetic induction to perform real-time measurement of AC current in power grids. Using constant current and linear compensation technology, they isolate and convert the measured current into a standard DC signal output. Operating on a safe voltage of DC12V or 24V, they can be widely used in industrial automation fields.","protected":false},"featured_media":3865,"template":"","productcat":[9,63],"class_list":["post-3859","product","type-product","status-publish","has-post-thumbnail","hentry","productcat-power-sensor","productcat-ac-current-sensor"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>BAK Series Split Core AC Current Transducer - ACREL<\/title>\n<meta name=\"description\" content=\"The Split-core BAK Series products utilize the principle of electromagnetic induction to perform real-time measurement of AC current in power grids. Using constant current and linear compensation technology, they isolate and convert the measured current into a standard DC signal output. Operating on a safe voltage of DC12V or 24V, they can be widely used in industrial automation fields.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/acrel.pl\/pl\/ru\/product\/bak-series-split-core-ac-current-transducer\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"BAK Series Split Core AC Current Transducer - ACREL\" \/>\n<meta property=\"og:description\" content=\"The Split-core BAK Series products utilize the principle of electromagnetic induction to perform real-time measurement of AC current in power grids. Using constant current and linear compensation technology, they isolate and convert the measured current into a standard DC signal output. Operating on a safe voltage of DC12V or 24V, they can be widely used in industrial automation fields.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/acrel.pl\/ru\/product\/bak-series-split-core-ac-current-transducer\/\" \/>\n<meta property=\"og:site_name\" content=\"ACREL\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-17T02:34:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/2-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1109\" \/>\n\t<meta property=\"og:image:height\" content=\"998\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/acrel.pl\/ru\/product\/bak-series-split-core-ac-current-transducer\/\",\"url\":\"https:\/\/acrel.pl\/ru\/product\/bak-series-split-core-ac-current-transducer\/\",\"name\":\"BAK Series Split Core AC Current Transducer - ACREL\",\"isPartOf\":{\"@id\":\"https:\/\/acrel.pl\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/acrel.pl\/ru\/product\/bak-series-split-core-ac-current-transducer\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/acrel.pl\/ru\/product\/bak-series-split-core-ac-current-transducer\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/2-1.jpg\",\"datePublished\":\"2026-09-17T02:27:35+00:00\",\"dateModified\":\"2026-09-17T02:34:27+00:00\",\"description\":\"The Split-core BAK Series products utilize the principle of electromagnetic induction to perform real-time measurement of AC current in power grids. Using constant current and linear compensation technology, they isolate and convert the measured current into a standard DC signal output. Operating on a safe voltage of DC12V or 24V, they can be widely used in industrial automation fields.\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/acrel.pl\/ru\/product\/bak-series-split-core-ac-current-transducer\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/acrel.pl\/ru\/product\/bak-series-split-core-ac-current-transducer\/#primaryimage\",\"url\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/2-1.jpg\",\"contentUrl\":\"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/2-1.jpg\",\"width\":1109,\"height\":998},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/acrel.pl\/#website\",\"url\":\"https:\/\/acrel.pl\/\",\"name\":\"ACREL\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/acrel.pl\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"BAK Series Split Core AC Current Transducer - ACREL","description":"The Split-core BAK Series products utilize the principle of electromagnetic induction to perform real-time measurement of AC current in power grids. Using constant current and linear compensation technology, they isolate and convert the measured current into a standard DC signal output. Operating on a safe voltage of DC12V or 24V, they can be widely used in industrial automation fields.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/acrel.pl\/pl\/ru\/product\/bak-series-split-core-ac-current-transducer\/","og_locale":"en_US","og_type":"article","og_title":"BAK Series Split Core AC Current Transducer - ACREL","og_description":"The Split-core BAK Series products utilize the principle of electromagnetic induction to perform real-time measurement of AC current in power grids. Using constant current and linear compensation technology, they isolate and convert the measured current into a standard DC signal output. Operating on a safe voltage of DC12V or 24V, they can be widely used in industrial automation fields.","og_url":"https:\/\/acrel.pl\/ru\/product\/bak-series-split-core-ac-current-transducer\/","og_site_name":"ACREL","article_modified_time":"2026-09-17T02:34:27+00:00","og_image":[{"width":1109,"height":998,"url":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/2-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/acrel.pl\/ru\/product\/bak-series-split-core-ac-current-transducer\/","url":"https:\/\/acrel.pl\/ru\/product\/bak-series-split-core-ac-current-transducer\/","name":"BAK Series Split Core AC Current Transducer - ACREL","isPartOf":{"@id":"https:\/\/acrel.pl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/acrel.pl\/ru\/product\/bak-series-split-core-ac-current-transducer\/#primaryimage"},"image":{"@id":"https:\/\/acrel.pl\/ru\/product\/bak-series-split-core-ac-current-transducer\/#primaryimage"},"thumbnailUrl":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/2-1.jpg","datePublished":"2026-09-17T02:27:35+00:00","dateModified":"2026-09-17T02:34:27+00:00","description":"The Split-core BAK Series products utilize the principle of electromagnetic induction to perform real-time measurement of AC current in power grids. Using constant current and linear compensation technology, they isolate and convert the measured current into a standard DC signal output. Operating on a safe voltage of DC12V or 24V, they can be widely used in industrial automation fields.","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/acrel.pl\/ru\/product\/bak-series-split-core-ac-current-transducer\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/acrel.pl\/ru\/product\/bak-series-split-core-ac-current-transducer\/#primaryimage","url":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/2-1.jpg","contentUrl":"https:\/\/acrel.pl\/wp-content\/uploads\/2026\/09\/2-1.jpg","width":1109,"height":998},{"@type":"WebSite","@id":"https:\/\/acrel.pl\/#website","url":"https:\/\/acrel.pl\/","name":"ACREL","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/acrel.pl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/product\/3859","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/media\/3865"}],"wp:attachment":[{"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/media?parent=3859"}],"wp:term":[{"taxonomy":"productcat","embeddable":true,"href":"https:\/\/acrel.pl\/pl\/wp-json\/wp\/v2\/productcat?post=3859"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}