Acrel-2000ES, an energy storage energy management system, is an energy storage EMS developed specifically for industrial and commercial energy storage cabinets and energy storage containers produced by equipment suppliers, energy storage integrators, and battery manufacturers.
Acrel-2000ES can connect the equipment inside the energy storage cabinet or energy storage container to the system through direct procurement or through a communication management machine or serial port server. The system structure is as follows:
Control Strategy
1 | Manual Control | Manual on-grid and off-grid switching is supported, and the PCS protocol must support to control it. |
2 | Plan Control | Users configure the electricity price template according to the price, set the charging and discharging power of PCS in different periods, and form a plan control template; you can set the plan daily and weekly. Adapt to the plan control in multiple regions and multiple electricity price environments. |
3 | Demand Control | The demand value is collected in real time by connecting the main meter on the low-voltage side of the transformer of the main incoming line. When the demand value reaches the limit value (settable), demand control is triggered. The system can reduces the power of charging and discharging for battery according to the configured parameters. |
4 | Dynamically Expand Transformer Capacity | By connecting the main meter to the low-voltage side of the transformer in the main incoming line, the transformer load rate is collected in real time. When the transformer load rate reaches the limit value (settable), the protection is triggered. The system can reduces the power of charging and discharging for battery according to the configured parameters. |
5 | Anti-backflow control | The reverse power data is collected in real time by connecting the main meter on the low-voltage side of the transformer of the main incoming line. When reverse power occurs and reaches the limit value (can be set), the system will perform static storage, reduce discharge, Charging and other actions according to the configured parameters..The system's antibackflow strategy is implemented through software protection. If you need to achieve faster response and more reliable protection, you need to add a corresponding reverse power protection device to immediately trip the protection when reverse flow is detected. |
6 | Backup Power | When an abnormality or failure occurs in the power grid, off grid operation is supported, and the PCS needs to support this function. |
7 | Supervision System Protection | Real-time reading of equipment operation data, combined with limit parameters for abnormal alarm protection and linkage control.
|
System Features
Product structure-integrated device
Monitor screen+Industrial computer=Industrial touch screen computer,became the software carrier of Acrel-2000ES | |
Application Environment | Product specifications |
Working temperature: -10~50℃ Storage temperature: -20~60℃ Relative humidity: 5~90% non-condensing Vibration: 1Grms, random 5 to 500Hz Impact: 20G acceleration, 11ms Waterproof: The front panel reaches IP65 protection level | Structure: full metal structure Appearance color: Matt silver all-aluminum alloy structure Installation: embedded Power supply: 12~24VDC Net weight: 2.65Kg |
Overall size: 339×216×66mm
Panel viewport: 339×216×5mm
Cabinet cutput: 327×204mm
No. | Equipment | Model | Picture | Product Description |
1 | Energy Storage Management System | Acrel-2000ES |
| Realize data collection and monitoring of energy storage equipment, statistical analysis, abnormal alarms, optimized control, data forwarding, etc.; Strategy control: planning curve, demand control, peak shaving and valley filling, backup power supply, etc. |
2 | Touch Screen Computer | PPX133L-512 |
| 1) Undertake system software 2) Visual display: display system operation information |
3 | AC Energy Meter | DTSD1352 |
| Integrate power parameters and electric energy measurement and assessment management, and provide various types of electric energy data statistics. It has harmonic and total harmonic content detection, with switch input and switch output to realize "remote signaling" and "remote control" functions, and has alarm output. With RS485 communication interface, MODBUS-RTU or DL/T645 protocol can be selected. |
4 | DC Energy Mete | DJSF1352 |
| The meter can measure voltage, current, power and forward and reverse electric energy in DC systems; it has infrared communication interface and RS-485 communication interface, and supports Modbus-RTU protocol and DLT645 protocol; it can have relay alarm output and switch input functions. |
5 | Temperature Monitor | ARTM-8 | | Suitable for multi-channel temperature measurement and control, supports 8-channel temperature measurement; each channel temperature measurement corresponds to 2-segment alarm, and the alarm direction and alarm value can be set arbitrarily on the relay output. |
6 | Gateway | ANet-2E8S1 |
| It can collect and summarize data from water meters, gas meters, electricity meters, computer protection and other equipment terminals according to different collection protocols; it provides multiple functions such as protocol conversion, transparent forwarding, data encryption and compression, data conversion, edge computing, etc.; it also provides real-time multi-task parallel processing Data collection and data forwarding can send platform data via multiple links. |
7 | Serial Server | APort |
| Function: Convert the status data of the "auxiliary system" and feed it back to the energy management system. 1) Switching, temperature adjustment, and complete power outage of the air conditioner (achieved by the secondary switch); 2) Upload the signals of each circuit breaker of the distribution cabinet; 3) Upload the internal power information of the UPS, etc.; 4) Access to the electric meter, BSMU and other equipments. |
8 | Remote signaling module | ARTU-KJ8 | 1) Feed back the status of each device and send relevant data to the serial port server; 2) Read the fire 1/0 signal and forward it to the upper layer (shutdown, event reporting, etc.); 3) Collect water immersion sensor information and forward it to the upper layer ( Flood signal event reporting); 4) Read the access control process sensor information and forward it to the upper layer (access control event reporting). |