Medical Isolation Power Panels

● Suitable for distribution system in group 2 medical location ● Using Q235A High Quality Cold Rolled Steel Plate ● Louver type heat dissipation fan ● Various installation types ● IP31

  • Szybka i bezpieczna logistyka
  • Próbka dostępna

Warning: Undefined array key 0 in /www/wwwroot/acrel.pl/wp-content/plugins/sytech-fronteditor/sytech-fronteditor.php on line 342

Warning: Attempt to read property "dup_id" on null in /www/wwwroot/acrel.pl/wp-content/plugins/sytech-fronteditor/sytech-fronteditor.php on line 342

General

Acrel Medical isolation power panels is designed for medical group 2 power supply requirements. Insulation monitoring device installed in IT system. Each output circuit has a circuit breaker with short circuit protection function; the output circuit in TN-S system has a circuit breaker with leakage protection, Products are divided into GGF-O series three-phase isolated power panels,GGF-I series single-phase isolated power panels, according to the number of input voltage phases. the products meet IEC60364-7-710:2016 Electrical installations of buildings—Part 7-710:Requirements for special installations or locations—Medical locations and IEC 61439-2:2011 Low-voltage switchgear and control gear assemblies—Part2:Power switchgear and control gear assemblies.

Parameter

ParametersGGF-IXGGGF-IXQGGF-OXFGGF-OXGGGF-OXQGGF-OXF
Rated voltage220V AC380V/220V AC
Rated Capacity3.15/5/6.3/10 KVA---3.15/5/6.3/10 KVA
Rated frequency50/60 Hz
Distribution circuitIT System:4 or 5 AC220V(can be customized)IT System:8 AC220V(can be customized)
---TN-S Systems:
Protection levelIP31IP34DIP31IP34D
InstallationFloor-standingEmbeddedFloor-standingEmbedded
Inlet and outletBottomBoth bottom and top have access linesBottomBoth bottom and top have access lines

Dimension

Related products

Product NameProduct ImageFunctions
AIM-M200 Medical Intelligent Insulation Monitor● Insulation monitoring for medical IT systems
● Load and temperature monitoring of isolation transformer
● Device disconnection monitoring
● LED indicators: On, Insulation, Overload, Overtemp
● Alarm relay output
● Test button
● Insulation fault location
● RS485 (MODBUS-RTU) + CAN
AID150 Alarm and Display Device● Remote monitoring
● LED indicators:On, Insulation, Overload, Overtemp
● Mute button
● Test button
● Auxiliary power supply: DC24V
● RS485(MODBUS-RTU)
ASG150 Signal Generator● Generating Fault Location Signal
● Detection of L1 and L2 disconnection
● LED indicators: On, Comm, Test
● CAN bus
● Auxiliary power supply: DC24V
ACLP10-24 Auxiliary Power Supply●  Auxiliary power supply to AID series
●  AC 220V input, DC 24V output
●  Completely Isolated Linear Transformer
●  Power-on indicator
AIL150-4/-8 Insulation Fault Locator● Insulation fault location in AC IT systems
● AIL150-4: 4 measuring channels
● AIL150-8: 8 measuring channels
● LED indicators: On, Comm
● CAN bus
● Auxiliary power supply: DC24V
AKH-0.66P26 Protective Current Sensor● Matching with AIM-M Series Insulation Monitor
● Maximum Current: 50A
● Transformation ratio: 2000:1
AITR Series Medical isolation transformer● Isolating transformers for medical IT systems
● Double insulation treatment, Electrostatic shielding layer
● PT100 temperature sensor
● Rated power: 3.15…10KVA
● CE