AMC16Z series multi channel din rail ac power meter is independently designed to meet the needs of the increasingly high precision power distribution management requirements of the data center. It is suitable for carious all-round inrelligent monitoring of terminal distribution equipment.
Type Model | Function description |
AMC16Z-ZA | Monitor the full power parameters of A+B double-way three-phase AC incomingcircuit,6-way switch state monitoring,2-way alarm output,2-way leakagemonitoring, 1-way temperature and humidity detection,1-way RS485communication, and phase-sequence detection. |
AMC16Z-FA | Monitor the full power parameters of 24 branches of A+B double-way ACoutgoing line,1-way RS485 communication and phase adjustment. |
AMC16Z-FAK24 | Monitor the full power parameters and switch state of 24 branches of A+Bdouble-way AC outgoing line,1-way RS485 communication and phaseadjustment. |
AMC16Z-FAK48 | Monitor the full power parameters and switch state of 48 branches of A+Bdouble-way AC outgoing line,1-way RS485 communication and phaseadjustment. |
AMC16Z-KA | Wet contact,monitoring A+B total 48 branch switch state,1-way RS485communication. |
AMC16Z-KD | Dry contact,monitoring A+B total 48 branch switch state,1-way RS485communication. |
AMC16Z-AC220V | AC220V extended power supply,and use when the monitoring circuit is beyond 96 branches of A+B |
AMC100-ZA | Monitoring the full power parameters of the A+B dual three-phase AC incoming circuit, 8 switching status inputs, 4 switching status outputs, 2 leakage monitoring, 1 temperature and humidity detection, 3 RS485 communications |
AMC100-FAK30 | Monitor the full power parameters and switch status of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication |
AMC100-FAK48 | Monitor the full power parameters and switch status of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication |
AMC100-FA30 | Monitor the full power parameters of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication |
AMC100-FA48 | Monitor the full power parameters of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication |
AMC100-KA30 | Wet contact, monitor the switching status of 30 branches A+B, 1 RS485 communication |
AMC100-KA48 | Wet contact, monitor the switching status of 48 branches A+B, 1 RS485 communication |
AMC100-KD30 | Dry contact, monitor the switching status of 30 branches A+B, 1 RS485 communication |
AMC100-KD48 | Dry contact, monitor the switching status of 48 branches A+B, 1 RS485 communication |
AMC100-FT30 | 1 way RS485 communication, 30 way temperature measurement |
AMC100-FT48 | 1 way RS485 communication, 48 way temperature measurement |