Acrel AKH-0.66/I Series Current Transformer can be used together with measuring instruments by collecting AC current signals. The measuring range of primary current is 15-3000A, and the secondary output is 5A or 1A. The measuring range is 5-120% of the rated value. Clamshell design, beautiful appearance, convenient wiring. The cover material is transparent polycarbonate, which can clearly see the secondary lead wiring. Square and square combination of holes, both through the cable, or through the busbar.

Acrel AKH-0.66/I Series Current Transformer can be used together with measuring instruments by collecting AC current signals.

Specification

* Model: AKH-0.66 I Series* Rated secondary current: 1A or 5A* Rated primary current: 10~3000A* Rated voltage: 660V AC* Test voltage: 3kV AC(1min)* Rated frequency: 50/60Hz
* Security factor: FS<5* Continuous overload: 120%In* Protection level: IP30* Operating temperature: -25℃~+50℃* Storage temperature: -40℃~+80℃* Relative humidity: ≤90%RH, no condensation

Technical Parameter

SpecificationRated Current Ratio(A)Precision Degree and Corresponding Rated Load (VA)Straight-Through TumsBus Spec(mm)/NumberMax. Cable Outer Diameter (mm)Installation
0.20.51
30I15/5(1)1.55/Ф22A
20/5(1)1.54
25-30/5(1)1.53
40-60/5(1)1.52
75-100/5(1)1.5130×10/1A、B
150-200/5(1)2.51
250/5(1)3.751
300-450/5(1)51
500/5(1)101
600/5101
40I10/5(1)1.510/Ф30A
15/5(1)1.58
20/5(1)1.55
25-30/5(1)1.54
40/5(1)1.53
50-75/5(1)1.52
100/5(1)1.5140×10/1A、C
150/5(1)2.51
200/5(1)2.51
250/5(1)3.751
300-450/5(1)51
500-800/5(1)101
1000/5(1)101
60I150/5(1)2.5160×10/160×6/1-2Ф44A、C
200-250/5(1)2.51
300-450/5(1)51
500-800/5(1)101
1000-1250/5(1)101
1500-2000/5(1)201
2500/5(1)301
80I150/5(1)2.5180×10/1Ф50A、C
200-250/5(1)2.51
300-400/5(1)51
500-800/5(1)101
1000-1250/5(1)101
1500-2000/5(1)201
2500-3000/5(1)301

Diagram of AKH-0.66/I Series Current Transformer

Spec. and sizeakh-0.66-i-series-current-transformer
TypeOutline sizeThrough sizeMounting sizeTolerance
(mm)
WHDaeΦMN
30I6078363111223457.5±1
40I7595454011314057.5
60I1021304561.521454257.5
80I118140458211526057.5

AKH-0.66/I Series Current Transformer can be installed in three ways: A-type straight plate is fixed, B-type bent plate is fixed, and C-type single plate pressure plate is fixed. Note that when the current transformer is in use, the secondary open circuit shall not be allowed, and the secondary outlet S2 shall be grounded.

diagram-of-akh-0.66-i-series-current-transformer