ADL200W-CT Wireless Dual-channel Single-phase Energy Meter

● Measurement: 1-phase dual-channel bi-directional AC Energy (kWh), Power, Current, Voltage and etc ● Response Rate: 50ms (current, voltage, power) ● Rated Voltage: 230~276Vac (direct connect) ● Rated Current: 120A AC (via paired CT) ● Communication: WiFI & LoRa (MODBUS) ; RS485 (MODBUS-RTU)

  • Fast And Safe Logistics
  • Sample Available

Main Features

Dual-channel Bidirection Metering

● Dual-channel metering for solar and grids

● For solar generation metering

● For grids import and solar export metering

● For ESS charge&discharge metering

● Forward&backward metering

● Optional WiFi & LoRa Comms.

Paired with Inverter for Zero Export

● 1-channel RS485 to communicate with inveter

● 100ms fast response time (voltage, current, power)

● Bidirectional metering

Diverse Electricity Parameters Measurement

● U (Voltage)

● I (Current)

● P (Power)

● Q (Reactive power)

● S (Apparent power)

● PF (Power factor)

● kWh (Kilowatt-hours)

● kVarh (Kilovar-hours)

Functions

FunctionDescriptions
Electric energy meteringActive energy metering (forward and reverse)
Reactive energy metering (forward and reverse)
Split-phase energy
Electric quantity measurementU, I
P, Q, S, PF, F
CommunicationRS485 、Wi-Fi HaLow

 Technical Parameters

ItemPerformance Parameters
Model SeriesADL200WADL400W
   MeasurementWiringSingle-phaseThree-phase four-wire
VoltageRated voltage230V3×230/400V
Input Range0.8Unom ~ 1.2Unom
Overload1.2 times rating (continuous)2 times the rating for 1 second
Power consumption<2w,    <10VA
Accuracy classError ±0.5%
CurrentMinimum current0.3A
Transitional current(Itr)1.5A
Basic current(Ib)30A
Maxinum current(Imax)D10:Imax = 80AD16:Imax = 120A
Power consumption<1W,    <1VA
Accuracy classError ±0.5%
PowerActive, reactive, apparent power, error ±1.0℅
Grid frequency50Hz, error ±0.5%
Response rate50ms (voltage, current, power)
Installation categoryCAT III
Overvoltage levelOVC III
MeteringActive electric energyClass 1 or B
Electromagnetic compatibilityE2
SecurityPower frequency withstand voltageBetween communication and signal input, AC3kV 1min
Insulation resistanceInput and output terminals to casing >100MΩ
CommunicationRS485 interfaceModbus RTU protocol; addr:1~ 247;Baudrate:1200bps-38400bps
Wi-Fi HaLowOperating frequency band:730MHz~950MHz
EnvironmentOperating temperature range-20℃~+55℃
Operating temperature range-20℃~+70℃
Storage temperature-20℃~+70℃
Relative humidity≤95% (without condensation)”Not suitable for damp environments”
Altitude≤2000m
IP ratingIP20 on terminal strip without protective housing and IP51 in protective housing, per IEC 60529
Pollution DegreeII
UC DegreeIII
Installation environmentIndoor use
Protect DegreeClass II (Double Insulation)
Usage environmentCabinet mounted(The outer shell cannot be touched)
Usage environmentM1
Transformer SafetycharacteristicsInsulation resistance: greater than 1000 MΩ under normal conditions;Electric strength resistance: It can withstand 4000V, 50Hz power frequency for 1 minute;Flame retardancy: Conforms to UL94-V0 level;
     Reference standardEN IEC 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirementsEN IEC 61010-2-030:2010 Safety requirements forelectrical equipment for measurement, control, andlaboratory use - Part 2-030: Particular requirements for equipment having testing or measuring circuitsEN IEC 61326-1:2021 Electrical equipment for measurement, control, and laboratory use - EMC requirements – Part 1: General requirementsEN IEC 61326-2-1:2021 Electrical equipment formeasurement, control, and laboratory use - EMCrequirements – Part 2-1: Particular requirements forelectromagnetic compatibility testing for electricalequipment for measurement, control, and laboratory useEN 50470-3 Electricity metering equipment (a.c.) - Part 3: Particular requirements - Static meters for active energy(class indexes A, B and C)